ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2014
Comparison of custom to standard TKA instrumentation with computed tomography.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 5 syntheses or guidelines pooled it.
- Computer-assisted surgery and patient-specific instrumentation improve the accuracy of tibial baseplate rotation in total knee arthroplasty compared to conventional instrumentation: a systematic review and meta-analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2022Pooled it
- Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis.BMC musculoskeletal disorders · 2019Pooled it
- The original Akagi line is the most reliable: a systematic review of landmarks for rotational alignment of the tibial component in TKA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2019Pooled it
- No difference in mechanical alignment and femoral component placement between patient-specific instrumentation and conventional instrumentation in TKA.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2015Pooled it
- No evidence of superiority in reducing outliers of component alignment for patient-specific instrumentation for total knee arthroplasty: a systematic review.Orthopaedic surgery · 2015Pooled it
- Sexual dimorphism of the posterior condylar offset of the femur and the medial posterior slope of the tibia in non-arthritic knees of Egyptian adults: an MRI study.Journal of orthopaedic surgery and research · 2023Trial
- Patient-specific Instrumentation Affects Rotational Alignment of the Femoral Component in Total Knee Arthroplasty: A Prospective Randomized Controlled Trial.Orthopaedic surgery · 2019Trial
- Applications and accuracy of 3D-printed surgical guides in traumatology and orthopaedic surgery: A systematic review and meta-analysis.Journal of experimental orthopaedics · 2024Article
- Two- and three-dimensional evaluations following handheld robot-assisted total knee arthroplasty.Journal of robotic surgery · 2024Article
- Comparison of post-operative three-dimensional and two-dimensional evaluation of component position for total knee arthroplasty.Knee surgery & related research · 2021Article
- Patient-Specific Instrumentation Accuracy Evaluated with 3D Virtual Models.Journal of clinical medicine · 2021Article
- Comparison of an Accelerometer-Based Portable Navigation System, Patient-Specific Instrumentation, and Conventional Instrumentation for Femoral Alignment in Total Knee Arthroplasty.Knee surgery & related research · 2017Article
- Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty.Acta orthopaedica · 2016Review
- Patient specific guides for total knee arthroplasty are ready for primetime.World journal of orthopedics · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThere is conflicting evidence whether custom instrumentation for total knee arthroplasty (TKA) improves component position compared to standard instrumentation. Studies have relied on long-limb radiographs limited to two-dimensional (2D) analysis and subjected to rotational inaccuracy. We used postoperative computed tomography (CT) to evaluate preoperative three-dimensional templating and CI to facilitate accurate and efficient implantation of TKA femoral and tibial components.
methodsWe prospectively evaluated a single-surgeon cohort of 78 TKA patients (51 custom, 27 standard) with postoperative CT scans using 3D reconstruction and contour-matching technology to preoperative imaging. Component alignment was measured in coronal, sagittal and axial planes.
resultsPreoperative templating for custom instrumentation was 87 and 79 % accurate for femoral and tibial component size. All custom components were within 1 size except for the tibial component in one patient (2 sizes). Tourniquet time was 5 min longer for custom (30 min) than standard (25 min). In no case was custom instrumentation aborted in favour of standard instrumentation nor was original alignment of custom instrumentation required to be adjusted intraoperatively. There were more outliers greater than 2° from intended alignment with standard instrumentation than custom for both components in all three planes. Custom instrumentation was more accurate in component position for tibial coronal alignment (custom: 1.5° ± 1.2°; standard: 3° ± 1.9°; p = 0.0001) and both tibial (custom: 1.4° ± 1.1°; standard: 16.9° ± 6.8°; p < 0.0001) and femoral (custom: 1.2° ± 0.9°; standard: 3.1° ± 2.1°; p < 0.0001) rotational alignment, and was similar to standard instrumentation in other measurements.
conclusionsWhen evaluated with CT, custom instrumentation performs similar or better to standard instrumentation in component alignment and accurately templates component size. Tourniquet time was mildly increased for custom compared to standard.
Indexed as
Identifiers
23979518What OpenQuestion holds