ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2013
Effects of acquisition time and reconstruction algorithm on image quality, quantitative parameters, and clinical interpretation of myocardial perfusion imaging.
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Standardized Uptake Value Using Thyroid Quantitative SPECT/CT for the Diagnosis and Evaluation of Graves' Disease: A Prospective Multicenter Study.BioMed research international · 2019Trial
- Quantitative assessment of graves' ophthalmopathy activity usingEJNMMI research · 2026Article
- Quantitative analysis ofEJNMMI physics · 2023Article
- Retrospective fractional dose reduction in Tc-99m cardiac perfusion SPECT/CT patients: A human and model observer study.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
- Reducing the small-heart effect in pediatric gated myocardial perfusion single-photon emission computed tomography.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017Article
- Comparative analysis of full-time, half-time, and quarter-time myocardial ECG-gated SPECT quantification in normal-weight and overweight patients.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017Article
- Adopting new gamma cameras and reconstruction algorithms: Do we need to re-establish normal reference values?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016Article
- How much shorter is better? Investigating image acquisition time reduction on left ventricular phase analysis for cardiac dyssynchrony.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2015Article
- Dependence of left ventricular functional parameters on image acquisition time in cardiac-gated myocardial perfusion SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2015Article
- Comparative analysis of iterative reconstruction algorithms with resolution recovery for cardiac SPECT studies. A multi-center phantom study.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundRecently introduced iterative reconstruction algorithms with resolution recovery (RR) and noise-reduction technology seem promising for reducing scan time or radiation dose without loss of image quality. However, the relative effects of reduced acquisition time and reconstruction software have not previously been reported. The aim of the present study was to investigate the influence of reduced acquisition time and reconstruction software on quantitative and qualitative myocardial perfusion single photon emission computed tomography (SPECT) parameters using full time (FT) and half time (HT) protocols and Evolution for Cardiac Software.
methodsWe studied 45 consecutive, non-selected patients referred for a clinically indicated routine 2-day stress/rest (99m)Tc-Sestamibi myocardial perfusion SPECT. All patients underwent an FT and an HT scan. Both FT and HT scans were processed according to our standard procedure with both ordered-subset expectation maximization (OSEM) + filtered back projection (FBP) reconstructions and a second reconstruction of HT scans was performed with the RR software producing three datasets for each patient for visual analysis (FT-OSEM, HT-OSEM, and HT-RR) and for quantitative analysis (FT-FBP, HT-FBP, and HT-RR). The datasets were analyzed using commercially available QGS/QPS software and read by two observers evaluating image quality and clinical interpretation. Image quality was assessed on a 10-cm visual analog scale score.
resultsHT imaging was associated with loss of image quality that was compensated for by RR reconstruction. HT imaging was also associated with increasing perfusion defect extents, an effect more pronounced using RR than FBP reconstruction. Compared to standard FT-FBP, HT-RR significantly reduced left ventricular volumes whereas HT-FBP increased end-systolic volume. HT imaging had no effect on measured left ventricular ejections fraction or measures of reversibility. Image interpretation found a higher level of concordance between FT-OSEM and HT-RR than between FT-OSEM and HT-OSEM without any observable systematic effects.
conclusionsUse of RR reconstruction algorithms compensates for loss of image quality associated with reduced scan time. Both HT acquisition and RR reconstruction algorithm had significant effects on motion and perfusion parameters obtained with standard software, but these effects were relatively small and probably of limited clinical importance. Although no systematic effects on image interpretation were observed, the influence on diagnostic accuracy remains to be determined.
Indexed as
Identifiers
23963600What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.