Evidence map›Paper›PMID 23963502›Full record

ArticleLab on a chip2013

Sensitive detection of protein and miRNA cancer biomarkers using silicon-based photonic crystals and a resonance coupling laser scanning platform.

Sherine George, Vikram Chaudhery, Meng Lu, Miki Takagi, Nabil Amro, Anusha Pokhriyal, Yafang Tan, Placid Ferreira, Brian T Cunningham

Abstract read
In one paragraph

Article in Lab on a chip, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
4.5field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 66 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Sherine GeorgeDepartment of Bioengineering, 1304 West Springfield Avenue, University of Illinois, Urbana-Champaign, Illinois, 61801, USA. bcunning@illinois.edu.
Vikram Chaudhery
Meng Lu
Miki Takagi
Nabil Amro
Anusha Pokhriyal
Yafang Tan
Placid Ferreira
Brian T Cunningham
University of Illinois Urbana-Champaign · US

Funding

Photonic Crystal Surfaces for Label-Free Detection and Fluorescence AmplificationR01GM086382 · NIGMS · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BOLLERO, GERMAN A, CUNNINGHAM, BRIAN T. · 2009 to 2012
$1.7M
NIGMS NIH HHS GM086382ANIGMS NIH HHS R01 GM086382
6 · The paper itself

Abstract

Enhancement of the fluorescent output of surface-based fluorescence assays by performing them upon nanostructured photonic crystal (PC) surfaces has been demonstrated to increase signal intensities by >8000×. Using the multiplicative effects of optical resonant coupling to the PC in increasing the electric field intensity experienced by fluorescent labels ("enhanced excitation") and the spatially biased funneling of fluorophore emissions through coupling to PC resonances ("enhanced extraction"), PC enhanced fluorescence (PCEF) can be adapted to reduce the limits of detection of disease biomarker assays, and to reduce the size and cost of high sensitivity detection instrumentation. In this work, we demonstrate the first silicon-based PCEF detection platform for multiplexed biomarker assay. The sensor in this platform is a silicon-based PC structure, comprised of a SiO2 grating that is overcoated with a thin film of high refractive index TiO2 and is produced in a semiconductor foundry for low cost, uniform, and reproducible manufacturing. The compact detection instrument that completes this platform was designed to efficiently couple fluorescence excitation from a semiconductor laser to the resonant optical modes of the PC, resulting in elevated electric field strength that is highly concentrated within the region <100 nm from the PC surface. This instrument utilizes a cylindrically focused line to scan a microarray in <1 min. To demonstrate the capabilities of this sensor-detector platform, microspot fluorescent sandwich immunoassays using secondary antibodies labeled with Cy5 for two cancer biomarkers (TNF-α and IL-3) were performed. Biomarkers were detected at concentrations as low as 0.1 pM. In a fluorescent microarray for detection of a breast cancer miRNA biomarker miR-21, the miRNA was detectable at a concentration of 0.6 pM.

Indexed as

LasersPhotonsSiliconBiomarkers, TumorImmunoassayInterleukin-3Microarray AnalysisMicroRNAsOptical PhenomenaProteinsSpectrometry, FluorescenceTumor Necrosis Factor-alphaBiomarkers, TumorInterleukin-3MicroRNAsProteinsSiliconTumor Necrosis Factor-alpha

Identifiers

PMID23963502
PMCPMC4522268
OpenAlexW1969507907

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.