Evidence map›Paper›PMID 23958947›Full record

ArticleJournal of biomedical optics2013

Optimization via specific fluorescence brightness of a receptor-targeted probe for optical imaging and positron emission tomography of sentinel lymph nodes.

Zhengtao Qin, David J Hall, Michael A Liss, Carl K Hoh, Christopher J Kane, Anne M Wallace, David R Vera

Open access · hybridAbstract read
In one paragraph

Article in Journal of biomedical optics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.9field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Molecular Imaging of the Glomerulus via Mesangial Cell Uptake of Radiolabeled Tilmanocept.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2019
    Article
  6. Article
  7. Article
  8. Fluorescence-Based Molecular Imaging of Porcine Urinary Bladder Sentinel Lymph Nodes.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2017
    Article
  9. Article
  10. Review
  11. Article
  12. Preclinical evaluation of robotic-assisted sentinel lymph node fluorescence imaging.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2014
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Zhengtao QinUniversity of California, San Diego, Department of Chemistry, La Jolla, California 92093, USA.
David J Hall
Michael A Liss
Carl K Hoh
Christopher J Kane
Anne M Wallace
David R Vera
University of California, San Diego · US

Funding

VIRAL MALIGNANCYP30CA023100 · NCI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DIANE M SIMEONE · 1985 to 2026
$124.9M
Targeted Smart Nanoplatforms for Multimode ImagingP50CA128346 · NCI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI STUPACK, DWAYNE G. · 2008 to 2012
$6.9M
NCI NIH HHS P30 CA023100NCI NIH HHS P50 CA128346
6 · The paper itself

Abstract

The optical properties of a receptor-targeted probe designed for dual-modality mapping of the sentinel lymph node (SLN) was optimized. Specific fluorescence brightness was used as the design criterion, which was defined as the fluorescence brightness per mole of the contrast agent. Adjusting the molar ratio of the coupling reactants, IRDye 800CW-NHS-ester and tilmanocept, enabled us to control the number of fluorescent molecules attached to each tilmanocept, which was quantified by H1 nuclear magnetic resonance spectroscopy. Quantum yields and molar absorptivities were measured for unconjugated IRDye 800CW and IRDye 800CW-tilmanocept (800CW-tilmanocept) preparations at 0.7, 1.5, 2.3, 2.9, and 3.8 dyes per tilmanocept. Specific fluorescence brightness was calculated by multiplication of the quantum yield by the molar absorptivity and the number of dyes per tilmanocept. It predicted that the preparation with 2.3 dyes per tilmanocept would exhibit the brightest signal, which was confirmed by fluorescence intensity measurements using three optical imaging systems. When radiolabeled with Ga68 and injected into the footpads of mice, the probe identified SLNs by both fluorescence and positron emission tomography (PET) while maintaining high percent extraction by the SLN. These studies demonstrated the feasibility of 800CW-tilmanocept for multimodal SLN mapping via fluorescence and PET-computed tomography imaging.

Indexed as

AnimalsDextransFemaleFluorescent DyesLymph NodesMiceMolecular ImagingOptical ImagingPositron-Emission TomographyRadiopharmaceuticalsSentinel Lymph Node BiopsyTechnetium Tc 99m PentetateDextransFluorescent Dyesgallium-diethylenetriaminepentaacetic acid-mannosyl-dextranRadiopharmaceuticalsTechnetium Tc 99m Pentetate

Identifiers

PMID23958947
PMCPMC3745642
OpenAlexW2085628454

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.