Evidence map›Paper›PMID 23958028›Full record

ArticleBiomaterials2013

Toward in vivo detection of hydrogen peroxide with ultrasound molecular imaging.

Emilia S Olson, Jahir Orozco, Zhe Wu, Christopher D Malone, Boemha Yi, Wei Gao, Mohammad Eghtedari, Joseph Wang, Robert F Mattrey

Open access · bronzeAbstract read
In one paragraph

Article in Biomaterials, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
8.0field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 104 citations in OpenAlex.

  1. Review
  2. Review
  3. Advanced Imaging Strategies Based on Intelligent Micro/Nanomotors.Cyborg and bionic systems (Washington, D.C.) · 2025
    Review
  4. Article
  5. Medical micro- and nanomotors in the body.Acta pharmaceutica Sinica. B · 2023
    Review
  6. Tailoring Functional Micromotors for Sensing.Research (Washington, D.C.) · 2023
    Article
  7. Review
  8. Review
  9. Medical Micro/Nanorobots in Precision Medicine.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2020
    Review
  10. Article
  11. Article
  12. Biomolecular Ultrasound and Sonogenetics.Annual review of chemical and biomolecular engineering · 2018
    Review
  13. Recent progress on micro- and nano-robots: towardsQuantitative imaging in medicine and surgery · 2018
    Article
  14. Review
  15. Article
  16. Article
  17. A HTheranostics · 2017
    Article
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Emilia S OlsonDepartment of Radiology, University of California, 410 Dickinson St., San Diego, CA 92103, United States.
Jahir Orozco
Zhe Wu
Christopher D Malone
Boemha Yi
Wei Gao
Mohammad Eghtedari
Joseph Wang
Robert F Mattrey
University of California, San Diego · US

Funding

Targeted Smart Nanoplatforms for Multimode ImagingP50CA128346 · NCI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI STUPACK, DWAYNE G. · 2008 to 2012
$6.9M
Traning Clinical Scientists in Radiological ImagingT32EB005970 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI Eric Y Chang, Rebecca Ann Rakow-Penner · 2007 to 2026
$3.2M
NCI NIH HHS P50 CA128346NIBIB NIH HHS T32 EB005970NIBIB NIH HHS T32-EB005970
6 · The paper itself

Abstract

We present a new class of ultrasound molecular imaging agents that extend upon the design of micromotors that are designed to move through fluids by catalyzing hydrogen peroxide (H₂O₂) and propelling forward by escaping oxygen microbubbles. Micromotor converters require 62 mm of H₂O₂ to move - 1000-fold higher than is expected in vivo. Here, we aim to prove that ultrasound can detect the expelled microbubbles, to determine the minimum H₂O₂ concentration needed for microbubble detection, explore alternate designs to detect the H₂O₂ produced by activated neutrophils and perform preliminary in vivo testing. Oxygen microbubbles were detected by ultrasound at 2.5 mm H₂O₂. Best results were achieved with a 400-500 nm spherical design with alternating surface coatings of catalase and PSS over a silica core. The lowest detection limit of 10-100 μm was achieved when assays were done in plasma. Using this design, we detected the H₂O₂ produced by freshly isolated PMA-activated neutrophils allowing their distinction from naïve neutrophils. Finally, we were also able to show that direct injection of these nanospheres into an abscess in vivo enhanced ultrasound signal only when they contained catalase, and only when injected into an abscess, likely because of the elevated levels of H₂O₂ produced by inflammatory mediators.

Indexed as

AnimalsCatalaseHydrogen-Ion ConcentrationHydrogen PeroxideMicrobubblesMicroscopy, Electron, ScanningMolecular ImagingNanospheresNeutrophilsRatsRats, Sprague-DawleyUltrasonicsCatalaseHydrogen PeroxideAbscessHydrogen peroxideMolecular imagingNanotechnologyUltrasound

Identifiers

PMID23958028
PMCPMC3794895
OpenAlexW2005272154

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.