A MEMS differential viscometric sensor for affinity glucose detection in continuous glucose monitoring.
Article in Journal of micromechanics and microengineering : structures, devices, and systems, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed, 35 citations in OpenAlex.
- Microfluidic chip connected to porous microneedle array for continuous ISF sampling.Drug delivery and translational research · 2022Article
- Development of a Portable Dielectric Biosensor for Rapid Detection of Viscosity Variations and Its In Vitro Evaluations Using Saliva Samples of COPD Patients and Healthy Control.Healthcare (Basel, Switzerland) · 2019Article
- Functionalized microneedles for continuous glucose monitoring.Nano convergence · 2018Review
- Design and Fabrication of a BiCMOS Dielectric Sensor for Viscosity Measurements: A Possible Solution for Early Detection of COPD.Biosensors · 2018Article
- A dielectric affinity glucose microsensor using hydrogel-functionalized coplanar electrodes.Microfluidics and nanofluidics · 2017Article
- A hydrogel-based glucose affinity microsensor.Sensors and actuators. B, Chemical · 2016Article
- A graphene-based affinity nanosensor for detection of low-charge and low-molecular-weight molecules.Nanoscale · 2016Article
- A differential dielectric affinity glucose sensor.Lab on a chip · 2014Article
- Glucose Measurement by Affinity Sensor and Pulsed Measurements of Fluidic Resistances: Proof of Principle.Journal of diabetes science and technology · 2014Article
- Boronic acids for sensing and other applications - a mini-review of papers published in 2013.Chemistry Central journal · 2014Article
- A MEMS Dielectric Affinity Glucose Biosensor.Journal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems · 2013Article
- A MEMS differential viscometric sensor for affinity glucose detection in continuous glucose monitoring.Journal of micromechanics and microengineering : structures, devices, and systems · 2013Article
- Continuous monitoring of glucose in subcutaneous tissue using microfabricated differential affinity sensors.Journal of diabetes science and technology · 2012Article
- Synthesis and development of poly(N-hydroxyethyl acrylamide)-ran-3-acrylamidophenylboronic acid polymer fluid for potential application in affinity sensing of glucose.Journal of diabetes science and technology · 2011Article
- Development, Fabrication, and Characterization of Hydrogel Based Piezoresistive Pressure Sensors with Perforated Diaphragms.Sensors and actuators. A, Physical · 2010Article
- Cell culture on MEMS platforms: a review.International journal of molecular sciences · 2009Review
- A MEMS affinity glucose sensor using a biocompatible glucose-responsive polymer.Sensors and actuators. B, Chemical · 2009Article
- Development of novel glucose sensing fluids with potential application to microelectromechanical systems-based continuous glucose monitoring.Journal of diabetes science and technology · 2008Article
- BioMEMS -Advancing the Frontiers of Medicine.Sensors (Basel, Switzerland) · 2008Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 4 institutions in 2 countries.
Funding
Abstract
Micromachined viscometric affinity glucose sensors have been previously demonstrated using vibrational cantilever and diaphragm. These devices featured a single glucose detection module that determines glucose concentrations through viscosity changes of glucose-sensitive polymer solutions. However, fluctuations in temperature and other environmental parameters might potentially affect the stability and reliability of these devices, creating complexity in their applications in subcutaneously implanted continuous glucose monitoring (CGM). To address these issues, we present a MEMS differential sensor that can effectively reject environmental disturbances while allowing accurate glucose detection. The sensor consists of two magnetically driven vibrating diaphragms situated inside microchambers filled with a boronic-acid based glucose-sensing solution and a reference solution insensitive to glucose. Glucose concentrations can be accurately determined by characteristics of the diaphragm vibration through differential capacitive detection. Our