Evidence map›Paper›PMID 23949235›Full record

ArticleClinical journal of the American Society of Nephrology : CJASN2013

Bioimpedance-guided fluid management in hemodialysis patients.

Ulrich Moissl, Marta Arias-Guillén, Peter Wabel, Néstor Fontseré, Montserrat Carrera, José Maria Campistol, Francisco Maduell

Registry-linked trialOpen access · bronzeAbstract read
In one paragraph

Article in Clinical journal of the American Society of Nephrology : CJASN, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01492634 (Clinical Investigation Plan Optimizing Fluid Status), which is not on this map. Cited by 69 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
69citing papers in PubMed, 2 pooled it
7.9field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01492634 nacompletednot on this map

Clinical Investigation Plan Optimizing Fluid Status

TypeinterventionalSponsorFrancisco MaduellRan2011 to 2012Enrolled56ConditionsHypotension During DialysisArmsPrescription of post-dialytic weight based on BCM device
3 · Its place in the literature

Who cites it

69 citing papers in PubMed, 2 syntheses or guidelines pooled it, 166 citations in OpenAlex.

  1. Guideline
  2. Pooled it
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Obstructive Sleep Apnea Severity and Overnight Body Fluid Shift before and after Hemodialysis.Clinical journal of the American Society of Nephrology : CJASN · 2015
    Trial
  8. Trial
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Observational
  15. Article
  16. Article
  17. SGLT2 Inhibitors Correct Fluid Overload in Adult Kidney Transplant Recipients-A Prospective Observational Study.Transplant international : official journal of the European Society for Organ Transplantation · 2024
    Observational
  18. Observational
  19. Observational
  20. Article

9 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Ulrich MoisslFresenius Medical Care Deutschland GmbH, Research and Development, Bad Homburg, Germany. ulrich.moissl@fmc-ag.com
Marta Arias-Guillén
Peter Wabel
Néstor Fontseré
Montserrat Carrera
José Maria Campistol
Francisco Maduell
Hospital Clínic de Barcelona · ESFresenius Medical Care (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

objectivesAchieving and maintaining optimal fluid status remains a major challenge in hemodialysis therapy. The aim of this interventional study was to assess the feasibility and clinical consequences of active fluid management guided by bioimpedance spectroscopy in chronic hemodialysis patients. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Fluid status was optimized prospectively in 55 chronic hemodialysis patients over 3 months (November 2011 to February 2012). Predialysis fluid overload was measured weekly using the Fresenius Body Composition Monitor. Time-averaged fluid overload was calculated as the average between pre- and postdialysis fluid overload. The study aimed to bring the time-averaged fluid overload of all patients into a target range of 0.5 ± 0.75 L within the first month and maintain optimal fluid status until study end. Postweight was adjusted weekly according to a predefined protocol.

resultsTime-averaged fluid overload in the complete study cohort was 0.9 ± 1.6 L at baseline and 0.6 ± 1.1 L at study end. Time-averaged fluid overload decreased by -1.20 ± 1.32 L (P<0.01) in the fluid-overloaded group (n=17), remained unchanged in the normovolemic group (n=26, P=0.59), and increased by 0.59 ± 0.76 L (P=0.02) in the dehydrated group (n=12). Every 1 L change in fluid overload was accompanied by a 9.9 mmHg/L change in predialysis systolic BP (r=0.55, P<0.001). At study end, 76% of all patients were either on time-averaged fluid overload target or at least closer to target than at study start. The number of intradialytic symptoms did not change significantly in any of the subgroups.

conclusionsActive fluid management guided by bioimpedance spectroscopy was associated with an improvement in overall fluid status and BP.

Indexed as

Electric ImpedanceAgedBlood PressureBlood VolumeBody CompositionBody FluidsBody WeightDehydrationDielectric SpectroscopyFemaleHumansMaleMiddle AgedNatriuretic Peptide, BrainQuality of LifeRenal DialysisNatriuretic Peptide, Brain

Identifiers

PMID23949235
PMCPMC3805085
OpenAlexW2146715480

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.