Evidence map›Paper›PMID 23942881›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2013

Patient-specific total knee arthroplasty: the importance of planning by the surgeon.

M Pietsch, O Djahani, M Hochegger, F Plattner, S Hofmann

Abstract readClinical Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
35citing papers in PubMed, 4 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

35 citing papers in PubMed, 4 syntheses or guidelines pooled it.

  1. Favourable alignment outcomes with MRI-based patient-specific instruments in total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018
    Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Trial
  6. Trial
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Patient-specific instruments for total knee arthroplasty can accurately predict the component size as used peroperative.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2017
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

M PietschDepartment of Orthopaedic Surgery, General and Orthopaedic Hospital Stolzalpe, 8852, Stolzalpe, Austria, martin.pietsch@lkh-stolzalpe.at.
O Djahani
M Hochegger
F Plattner
S Hofmann

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of the study was to evaluate the accuracy of the planning of the patient-specific pin guides in total knee arthroplasty (TKA). This planning was performed primarily by a technician of the company and offered to the surgeon. All parameters of the implantation can either be modified or accepted by the surgeon. The hypothesis was that the plan needs preoperative intervention by the surgeon.

methodsA prospective study in 50 patients was carried out. All patients received the same posterior-stabilised implant with patient-specific instrumentation. All surgical parameters (coronal, sagittal, rotational alignment, femoral and tibial resection levels and implant sizes) were checked by the orthopaedic surgeon and changed if necessary.

resultsPreoperatively, the femoral size was changed in 8 patients (16 %), the femoral flexion in 23 patients (46 %), the femoral shift in 34 patients (68 %), the tibial size in 24 patients (48 %) and the tibial rotation in all patients. The epicondylar axis was accepted in 47 patients (94 %) in the technician plan. Mean planning time was 8 ± 4 min. Intraoperatively, the femoral anterior-posterior size was in 50 patients (100 %) the same as in the surgeon and in 42 patients (84 %) the same as in the technician plan (p = 0.003). The tibial component implanted was in 42 patients (84 %) the same as in the surgeon and in 19 patients (38 %) the same as in the technician plan (p < 0.0001). A femoral distal recut was necessary in 31 patients (62 %) and a change of the tibial proximal cut in 17 patients (34 %) during surgery. Intraoperatively, no changes of the femoral and tibial alignment, the femoral anterior-posterior size, the femoral flexion, the femoral shift, the femoral and tibial rotation were necessary. Postoperatively, the coronal mechanical overall axis was within ±3° in 47 patients (94 %) with a maximum deviation of 5.6°.

conclusionsSignificant changes of the technician plan were necessary to get an accurate preoperative plan. Intraoperative changes were significant less compared to the surgeon than to the technician plan. No major changes (alignment, femoral anterior-posterior size and rotation) of the surgeon plan were necessary. Surgeons using patient-specific pin guides in TKA may verify the default plan provided by the technician. A blind reply on the technician plan may be not recommended. LEVEL OF EVIDENCE: Therapeutic study, Level III.

Indexed as

Magnetic Resonance ImagingAgedAged, 80 and overAnatomic LandmarksArthroplasty, Replacement, KneeBone MalalignmentFemaleHumansImaging, Three-DimensionalKnee ProsthesisMaleMiddle AgedOsteoarthritis, KneePostoperative ComplicationsPreoperative CareProspective Studies

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.