Trial reportJACC. Cardiovascular imaging2013
Predictors of inaccurate coronary arterial stenosis assessment by CT angiography.
Trial report in JACC. Cardiovascular imaging, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 35 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Coronary Evaluation Using Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors: "CORE-64" Study
Functional and Anatomical Testing in Intermediate Risk Chest Pain Patients With Severe Coronary Calcium Score
Who cites it
35 citing papers in PubMed, 88 citations in OpenAlex.
- Association of high-risk CT coronary artery plaque features with major adverse cardiovascular events: a prespecified secondary analysis of the DISCHARGE trial.European radiology · 2026Trial
- Impact of smoking in patients with suspected coronary artery disease in the randomised DISCHARGE trial.European radiology · 2024Trial
- Diffusely impaired myocardial perfusion in patients with suspected coronary artery disease: Clinical utility of relative perfusion.Clinical physiology and functional imaging · 2026Article
- High-Z Contrast Media for Coronary Photon-counting Detector CT Angiography: Improved Quantification of Calcified Stenoses.Investigative radiology · 2026Article
- Ultra-high resolution photon-counting detector coronary CT angiography: diagnostic accuracy in patients with high Agatston scores.European radiology · 2026Article
- Comparison of Non-Invasive and Invasive Diagnostic Methods for Coronary Artery Disease: Single-Centre Data.Medicina (Kaunas, Lithuania) · 2026Article
- Utility of Tei Index, carotid IMT, and crouse score in coronary artery calcification assessment and MACCE prediction in elderly patients.Frontiers in cardiovascular medicine · 2026Article
- Definitions and standardized endpoints for the use of drug-coated balloon in coronary artery disease: consensus document of the Drug Coated Balloon Academic Research Consortium.European heart journal · 2025Article
- Incidence and predictors of discrepancies in radiology resident interpretations of coronary CT in the emergency department.BMC medical imaging · 2025Article
- Definitions and standardized endpoints for the use of drug-coated balloon in coronary artery disease: consensus document of the Drug Coated Balloon Academic Research Consortium.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025Article
- Predictors of Diagnostic Inaccuracy of Detecting Coronary Artery Stenosis by Preprocedural CT Angiography in Patients Prior to Transcatheter Aortic Valve Implantation.Diagnostics (Basel, Switzerland) · 2025Article
- Multienergy cardiovascular CT imaging: current state and future.The British journal of radiology · 2025Review
- [The challenging patient-recommendations and solutions].Radiologie (Heidelberg, Germany) · 2024Review
- The Role of Coronary Computed Tomography Angiography in the Diagnosis, Risk Stratification, and Management of Patients with Diabetes and Chest Pain.Reviews in cardiovascular medicine · 2024Review
- CT coronary fractional flow reserve based on artificial intelligence using different software: a repeatability study.BMC medical imaging · 2024Article
- Computed tomographic angiography measures of coronary plaque in clinical trials:Frontiers in cardiovascular medicine · 2024Review
- Cardiovascular Magnetic Resonance and Cardiovascular Computed Tomography in the Present and Future Cardiology.Arquivos brasileiros de cardiologia · 2023Article
- Coronary computed tomography angiography assessment of relationship between right coronary artery-aorta angle and the development of coronary artery disease.Quantitative imaging in medicine and surgery · 2023Article
- Investigation of the Relationship between Right Coronary Artery-Aorta Angle and Coronary Artery Disease and Associated Risk Factors.Journal of clinical medicine · 2023Article
- Effect of different injection rates and doses of contrast medium on the image quality of computed tomographic angiography in African grey parrots (Psittacus erithacus).BMC veterinary research · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 5 institutions in 4 countries.
Funding
Abstract
objectivesThis study sought to investigate the clinical and imaging characteristics associated with diagnostic inaccuracy of computed tomography angiography (CTA) for detecting obstructive coronary artery disease (CAD) defined by quantitative coronary angiography (QCA).
backgroundAlthough diagnostic performance metrics of CTA have been reported, there are sparse data on predictors of diagnostic inaccuracy by CTA.
methodsThe clinical characteristics of 291 patients (mean age: 59 ± 10 years; female: 25.8%) enrolled in the multicenter CorE-64 (Coronary Artery Evaluation Using 64-Row Multi-detector Computed Tomography Angiography) study were examined. Pre-defined CTA segment-level characteristics of all true-positive (N = 237), false-positive (N = 115), false-negative (FN) (N = 159), and a random subset of true-negative segments (N = 511) for ≥50% stenosis with QCA as the reference standard were blindly abstracted in a central core laboratory. Factors independently associated with corresponding levels of CTA diagnostic inaccuracies on a patient level and coronary artery segment level were determined using multivariable logistic regression models and generalized estimating equations, respectively.
resultsAn Agatston calcium score of ≥1 per patient (odds ratio [OR]: 5.2; 95% confidence interval [CI]: 1.1 to 24.6) and the presence of within-segment calcification (OR: 10.2; 95% CI: 5.2 to 19.8) predicted false-positive diagnoses. Conversely, absence of within-segment calcification was an independent predictor of an FN diagnosis (OR: 2.0; 95% CI: 1.2 to 3.5). Prior percutaneous revascularization was independently associated with patient-level misdiagnosis of obstructive CAD (OR: 4.2; 95% CI: 1.6 to 11.2). Specific segment characteristics on CTA, notably segment tortuosity (OR: 3.5; 95% CI: 2.4 to 5.1), smaller luminal caliber (OR: 0.48; 95% CI: 0.36 to 0.63 per 1-mm increment), and juxta-arterial vein conspicuity (OR: 2.1; 95% CI: 1.4 to 3.2), were independently associated with segment-level misdiagnoses. Attaining greater intraluminal contrast enhancement independently lowered the risk of an FN diagnosis (OR: 0.96; 95% CI: 0.94 to 0.99 per 10-Hounsfield unit increment).
conclusionsWe identified clinical and readily discernible imaging characteristics on CTA predicting inaccurate CTA diagnosis of obstructive CAD defined by QCA. Knowledge and appropriate considerations of these features may improve the diagnostic accuracy in clinical CTA interpretation. (Diagnostic Accuracy of Multi-Detector Spiral Computed Tomography Angiography Using 64 Detectors [CORE-64]; NCT00738218).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.