ArticleThe journal of extra-corporeal technology2013

Vacuum assist: angel or demon CON.

Timothy W Willcox

Abstract read
In one paragraph

Article in The journal of extra-corporeal technology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Timothy W WillcoxGreen Lane Cardiothoracic Unit, Auckland City Hospital, Auckland, New Zealand. timw@adhb.govt.nz

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Vacuum-assisted venous drainage (VAVD) to enhance venous return during cardiopulmonary bypass (CPB) was described as early as 1958 but was not widely used until the late 1990s. VAVD was initially used to facilitate the use of smaller cannulas with ministernotomy but was increasingly used to allow reduction in CPB circuit size while maintaining CPB flow rates. This innovation was made without planned consideration to CPB circuit design, most critically that of the venous reservoir. Clinical reports of prime reduction facilitated by VAVD in both adult and pediatric CPB were associated with reduced nadir hematocrit and rates of transfusion that encouraged the proliferation of VAVD in CPB. Concomitantly, investigators have reported both in vitro and in vivo significantly increased arterial emboli associated with the use of VAVD, mostly related to accelerated venous air entrainment. In vitro studies continue to confirm this association and likely underestimate the resulting embolic load as a result of flawed study design. While the evidence for VAVD is equivocal, our understanding of the clinical impact of gaseous microemboli in CPB is similarly limited, most likely confined to blood-brain barrier disruption. It is only after two decades that CPB component design is receiving serious attention in terms of air handling. The ethics of innovation in the field of CPB warrant careful consideration. The application of VAVD is not without consequence.

Indexed as

VeinsAdultCardiopulmonary BypassDrainageEmbolism, AirEquipment DesignEquipment Failure AnalysisHumansPerfusionSuctionTechnology Assessment, Biomedical

Identifiers

PMID23930383
PMCPMC4557579

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.