ReviewYonsei medical journal2013
Stent evaluation with optical coherence tomography.
Review in Yonsei medical journal, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 29 citations in OpenAlex.
- Randomized comparison of acute stent malapposition between platinum-chromium versus cobalt-chromium everolimus-eluting stents.The international journal of cardiovascular imaging · 2015Trial
- Impact of statin treatment on strut coverage after drug-eluting stent implantation.Yonsei medical journal · 2015Trial
- Prospective and systematic analysis of unexpected requests for non-cardiac surgery or other invasive procedures during the first year after drug-eluting stent implantation.Yonsei medical journal · 2014Trial
- Frequency-aware optical coherence tomography image super-resolution via conditional generative adversarial neural network.Biomedical optics express · 2023Article
- DPSF: a Novel Dual-Parametric Sigmoid Function for Optical Coherence Tomography Image Enhancement.Medical & biological engineering & computing · 2022Article
- Automated Segmentation of Bioresorbable Vascular Scaffold Struts in Intracoronary Optical Coherence Tomography Images.International Conference on Bioinformatics and Biomedical Engineering : [proceedings]. International Conference on Bioinformatics and Biomedical Engineering · 2017Article
- Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.Heart and vessels · 2016Article
- Safety and efficacy of a novel technique in the use of fractional flow reserve in complex coronary artery lesions.Chinese medical journal · 2015Article
- Optical coherence tomographic observation of morphological features of neointimal tissue after drug-eluting stent implantation.Yonsei medical journal · 2014Article
- Serial changes of neointimal tissue after everolimus-eluting stent implantation in porcine coronary artery: an optical coherence tomography analysis.BioMed research international · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Optical coherence tomography (OCT) has been recently applied to investigate coronary artery disease in interventional cardiology. Compared to intravascular ultrasound, OCT is able to visualize various vascular structures more clearly with higher resolution. Several validation studies have shown that OCT is more accurate in evaluating neointimal tissue after coronary stent implantation than intravascular ultrasound. Novel findings on OCT evaluation include the detection of strut coverage and the characterization of neointimal tissue in an in-vivo setting. In a previous study, neointimal healing of stent strut was pathologically the most important factor associated with stent thrombosis, a fatal complication, in patients treated with drug-eluting stent (DES). Recently, OCT-defined coverage of a stent strut was proposed to be related with clinical safety in DES-treated patients. Neoatherosclerosis is an atheromatous change of neointimal tissue within the stented segment. Clinical studies using OCT revealed neoatherosclerosis contributed to late-phase luminal narrowing after stent implantation. Like de novo native coronary lesions, the clinical presentation of OCT-derived neoatherosclerosis varied from stable angina to acute coronary syndrome including late stent thrombosis. Thus, early identification of neoatherosclerosis with OCT may predict clinical deterioration in patients treated with coronary stent. Additionally, intravascular OCT evaluation provides additive information about the performance of coronary stent. In the near future, new advances in OCT technology will help reduce complications with stent therapy and accelerating in the study of interventional cardiology.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.