ArticleTexas Heart Institute journal2013
Intraoperative device closure of atrial septal defects with minimal transthoracic invasion: a single-center experience.
Article in Texas Heart Institute journal, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 9 citations in OpenAlex.
- Simultaneous transthoracic intervention for multiple cardiac defects in children.Translational pediatrics · 2021Article
- Open heart surgery or echocardiographic transthoracic or percutaneous closure in secundum atrial septal defect: a developing approach in one Chinese hospital.Journal of cardiothoracic surgery · 2020Article
- Clinical evaluation of percutaneous and intra-operative device closure of atrial septal defects under transesophageal echocardiographic guidance: one center experience and mid-term follow-up.Journal of cardiothoracic surgery · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Atrial septal defect is one of the most common congenital heart defects. Open-heart repair via midline sternotomy or right thoracotomy and cardiopulmonary bypass has been considered the standard treatment for the closure of atrial septal defects, but transcatheter closure with the Amplatzer septal occluder has recently become a viable option. We have adopted a 3rd alternative: intraoperative device closure with minimal transthoracic invasion. From May 2007 through June 2011, 250 patients with secundum atrial septal defect underwent cardiac surgery at our institution. Open-heart repair with cardiopulmonary bypass was performed in 72 patients, and intraoperative device closure was performed in 178 patients. This minimally invasive approach, which required a full evaluation of the atrial septal defect by transthoracic echocardiography, was performed by deploying the device through the delivery sheath to occlude the atrial septal defect. The approach was successful in 175 of the 178 patients. The size of the implanted occluder ranged from 12 to 46 mm in diameter. Minor complications included transient arrhythmias (n=7) and pleural effusion (n=25). After complete release, the intraoperative occluder device dislodged in the right atrium in 3 patients, who then underwent immediate surgical repair with cardiopulmonary bypass. All discharged patients were monitored for 2.3 years to 5 years. As monotherapy, intraoperative device closure of atrial septal defect with minimal transthoracic invasion is a safe and feasible technique. It is particularly beneficial for elderly patients or patients with pulmonary hypertension and is associated with better cosmetic results and less trauma than is surgical closure.
Indexed as
Identifiers
23914014PMC3709217W2188291369What OpenQuestion holds
Registered trials