In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
5.9field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 82 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Jannet J H BakkerDepartment of Obstetrics and Gynaecology, Academic Medical Center, Meibergdreef 9, Amsterdam, Netherlands, 1105 AZ.
Petra F Janssen
Karlijn van Halem
Birgit Y van der Goes
Dimitri N M Papatsonis
Joris A M van der Post
Ben Willem J Mol
Academic Medical Center · NLAmphia Ziekenhuis · NLAmsterdam UMC Location VUmc · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUterine contractions can be registered by external tocodynamometry (ET) or, after rupture of the membranes, by internal tocodynamometry (IT). Monitoring of the frequency of contractions is important especially when intravenous oxytocin is used as excessive uterine activity (hyperstimulation or tachysystole) can cause fetal distress. During induction of labour as well as during augmentation with intravenous oxytocin, some clinicians choose to monitor frequency and strength of contractions with IT rather than with ET as an intrauterine pressure catheter measures intrauterine activity more accurately than an extra-abdominal tocodynamometry device. However, insertion of an intrauterine catheter has higher costs and also potential risks for mother and child.

objectivesTo assess the effectiveness of IT compared with using ET when intravenous oxytocin is used for induction or augmentation of labour. SEARCH

methodsWe searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 March 2013) and PubMed (1966 to 6 April 2013). SELECTION CRITERIA: We included all published randomised controlled trials with data from women in whom IT was compared with ET in induced or augmented labour with oxytocin. We excluded trials that employed quasi-randomised methods of treatment allocation. We found no unpublished or ongoing studies on this subject. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial eligibility and risk of bias, and independently extracted data. Data were checked for accuracy. Where necessary, we contacted study authors for additional information. MAIN

resultsThree studies involving a total of 1945 women were included. Overall, risk of bias across the three trials was mixed. No serious complications were reported in the trials and no neonatal or maternal deaths occurred. The neonatal outcome was not statistically different between groups: Apgar score less than seven at five minutes (RR 1.78, 95% CI 0.83 to 3.83; three studies, n = 1945); umbilical artery pH less than 7.15 (RR 1.31, 95% CI 0.95 to 1.79; one study, n = 1456); umbilical artery pH less than 7.16 (RR 1.23, 95% CI 0.39 to 3.92; one study, n = 239); admission to the neonatal intensive care unit (RR 0.34, 95% CI 0.07 to 1.67; two studies, n = 489); and more than 48 hours hospitalisation (RR 0.92, 95% CI 0.71 to 1.20; one study, n = 1456). The pooled risk for instrumental delivery (including caesarean section, ventouse and forceps extraction) was not statistically significantly different (RR 1.05, 95% CI 0.91 to 1.21; three studies, n = 1945). Hyperstimulation was reported in two studies (n = 489), but there was no statistically significant difference between groups (RR 1.21, 95% CI 0.78 to 1.88). AUTHORS'

conclusionsThis review found no differences between the two types of monitoring (internal or external tocodynamometry) for any of the maternal or neonatal outcomes. Given that this review is based on three studies (N = 1945 women) of moderate quality, there is insufficient evidence to recommend the use of one form of tocodynamometry over another for women where intravenous oxytocin was administered for induction or augmentation of labour.

Indexed as

FemaleHumansInjections, IntravenousLabor, InducedOxytocicsOxytocinPregnancyPregnancy OutcomeRandomized Controlled Trials as TopicUterine ContractionUterine MonitoringOxytocicsOxytocin

Identifiers

PMID23913521
PMCPMC11569888
OpenAlexW1902553746

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.