Evidence map›Paper›PMID 23912935›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2014

Calcium phosphate cement augmentation after volar locking plating of distal radius fracture significantly increases stability.

Hans Kainz, Enrico Dall'Ara, Anna Antoni, Heinz Redl, Philippe Zysset, Patrick Weninger

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Experimental testing of fracture fixation plates: A review.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2022
    Review
  3. Article
  4. Review
  5. Review
  6. Emerging Technologies in Distal Radius Fracture Fixation.Current reviews in musculoskeletal medicine · 2019
    Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Hans KainzLudwig Boltzmann Institute for Experimental and Clinical Traumatology, Donaueschingenstraße 13, 1200, Vienna, Austria.
Enrico Dall'Ara
Anna Antoni
Heinz Redl
Philippe Zysset
Patrick Weninger
Ludwig Boltzmann Institute for Experimental and Clinical Traumatology · ATTU Wien · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeDistal radius fractures represent the most common fractures in adults. Volar locking plating to correct unstable fractures has become increasingly popular. Although reasonable primary reduction is possible in most cases, maintenance of reduction until the fracture is healed is often problematic in osteoporotic bone. To our knowledge, no biomechanical studies have compared the effect of enhancement with biomaterial on two different volar fixed-angle plates.

methodsHuman fresh-frozen cadaver pairs of radii were used to simulate an AO/OTA 23-A3 fracture. In a total of four groups (n = 7 for each group), two volar fixed-angle plates (Aptus 2.5 mm locking fracture plate, Medartis, Switzerland and VA-LCP two-column distal radius plate 2.4, volar, Synthes, Switzerland) with or without an additional injection of a biomaterial (Hydroset Injectable HA Bone Substitute, Stryker, Switzerland) into the dorsal comminution zone were used to fix the distal metaphyseal fragment. Each specimen was tested load-controlled under cyclic loading with a servo-hydraulic material testing machine. Displacement, stiffness, dissipated work and failure mode were recorded.

resultsImproved mechanical properties (decreased displacement, increased stiffness, decreased dissipated work) were found in both plates if the biomaterial was additionally injected. Improvement of mechanical parameters after biomaterial injection was more evident in the Synthes plate compared to the Aptus plate. Pushing out of the screws was noticed as a failure mode only in samples lacking supplementary biomaterial.

conclusionsInjection of a biomaterial into the dorsal comminution zone increases stability after volar locking plating of distal radius fractures in vitro.

Indexed as

Bone PlatesAgedBiomechanical PhenomenaBone CementsBone SubstitutesCadaverCalcium PhosphatesHumansRadius FracturesBone CementsBone Substitutescalcium phosphateCalcium Phosphates

Identifiers

PMID23912935
OpenAlexW2073987501

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.