ArticleJournal of diabetes science and technology2013
Higher accuracy of self-monitoring of blood glucose in insulin-treated patients in Germany: clinical and economical aspects.
Article in Journal of diabetes science and technology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 14 citations in OpenAlex.
- Budget Impact of Improved Diabetes Management by Utilization of Glucose Meters With a Color-Range Indicator-Comparison of Five European Healthcare Systems.Journal of diabetes science and technology · 2020Article
- Pan-European Economic Analysis to Identify Cost Savings for the Health Care Systems as a Result of Integrating Glucose Monitoring Based Telemedical Approaches Into Diabetes Management.Journal of diabetes science and technology · 2019Article
- Toward a Framework for Outcome-Based Analytical Performance Specifications: A Methodology Review of Indirect Methods for Evaluating the Impact of Measurement Uncertainty on Clinical Outcomes.Clinical chemistry · 2019Review
- Economic Value of Improved Accuracy for Self-Monitoring of Blood Glucose Devices for Type 1 and Type 2 Diabetes in England.Journal of diabetes science and technology · 2018Article
- Improvement of Metabolic Control and Diabetes Management in Insulin-Treated Patients Results in Substantial Cost Savings for the German Health System.Journal of diabetes science and technology · 2018Observational
- Economic Value of Improved Accuracy for Self-Monitoring of Blood Glucose Devices for Type 1 Diabetes in Canada.Journal of diabetes science and technology · 2015Article
- Impact of a reduced error range of SMBG in insulin-treated patients in Germany.Journal of diabetes science and technology · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAccuracy standards of blood glucose (BG) meters are currently under review. Revised standards are expected to tighten accuracy requirements. Regarding clinical and financial impact of BG meter accuracy, very little data are available. The aim of this study was to analyze potential cost savings related to higher accuracy of glucose meters in Germany.
methodsAs a model for calculation, a reduction of meter error from 20% to 5% was applied. The health economic analysis was based on four main pillars: (1) number of insulin-treated patients; (2) costs for glucose monitoring in Germany; (3) data of a modeling analysis on the impact on hypoglycemic episodes, glycosylated hemoglobin (HbA1c), and, subsequently, myocardial infarctions; and (4) costs of diabetes-related complications in Germany. A reduction of meter error from 20% to 5% was identified to be associated with a 10% reduction in severe hypoglycemic episodes and a 0.39% reduction in HbA1c, which translates into a 0.5% reduction of myocardial infarctions.
resultsAccording to the health economic analysis, the reduction in severe hypoglycemic episodes and myocardial infarctions led to cost savings of €24.14 per patient per year. Considering 390,000 type 1 diabetes patients or 2.3 million insulin-treated patients in Germany, these savings could be equal to a reduction in health care expenditures of more than €9.4 million and €55.5 million, respectively.
conclusionsPotential cost savings and clinical effects due to higher accuracy of BG meters should provide an impetus to implementation of tighter accuracy standards and development of glucose meters that provide highest possible accuracy.