Evidence map›Paper›PMID 23904375›Full record

ArticleJournal of Huazhong University of Science and Technology. Medical sciences = Hua zhong ke ji da xue xue bao. Yi xue Ying De wen ban = Huazhong keji daxue xuebao. Yixue Yingdewen ban2013

In vivo testing of canine prosthetic femoral components with HA-Ti ladder-type coating on vacuum plasma-sprayed Ti substrate.

Xian-Lin Zeng, Jing-Feng Li, Shu-Hua Yang, Qi-Xin Zheng, Zhen-Wei Zou

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of Huazhong University of Science and Technology. Medical sciences = Hua zhong ke ji da xue xue bao. Yi xue Ying De wen ban = Huazhong keji daxue xuebao. Yixue Yingdewen ban, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Xian-Lin ZengDepartment of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China. zxlxhh@163.com.
Jing-Feng LiDepartment of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Shu-Hua YangDepartment of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Qi-Xin ZhengDepartment of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Zhen-Wei ZouDepartment of Orthopedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430022, China.
Huazhong University of Science and Technology · CNUnion Hospital · CNWuhan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of the present study was to observe the structure and functional change of the bone-coating-prosthesis interface in vivo and to evaluate the histocompatibility of self-made prosthetic femoral components in the body and the degree of their bonding with the surrounding bone tissues as well as their stability. Six mature beagle dogs underwent bilateral hip replacement with prosthetic femur components. Three groups were established in terms of different coating of prothesis (four joints in each group): atmosphere (A) plasma-sprayed pure titanium (Ti) prosthetic joint with hydroxyapatite (HA) coating (HA+Ti+A group); vacuum (V) plasma-sprayed pure Ti prosthetic joint with HA coating (HA+Ti+V group); vacuum plasma-sprayed pure Ti prosthetic joint with Ti-HA stepped coating (Ti+HAG+Ti+V group). The hip joints were functionally evaluated, and subjected to X-ray examination, biomechanics inspection, and histological examination. As a result, X-ray imaging revealed all prosthetic joints were in a good location and no dislocation of joint was found. Shear strength of interface was significantly higher in Ti+HAG+Ti+V group than in HA+Ti+V group (P<0.05) and HA+Ti+A group (P<0.05) at 28th week. Histological examination showed the amount of newborn bone in Ti+HAG+Ti+V group was more than in HA+Ti+V group and HA+Ti+A group after 28 weeks. It was suggested that vacuum plasma-sprayed pure Ti prosthetic joint with TI-HA stepped coating could improve the bonding capacity of bone-prosthesis, enhance the stability of prosthesis, and increase the fixion of prosthetic femoral components because of better bone growth. This new type of biological material in prosthetic femoral components holds promises for application in clinical practice.

Indexed as

AnimalsBiomechanical PhenomenaBone DevelopmentCoated Materials, BiocompatibleDogsDurapatiteFemurProstheses and ImplantsTitaniumVacuumCoated Materials, BiocompatibleDurapatiteTitanium

Identifiers

PMID23904375
OpenAlexW1511543959

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.