ArticleLab on a chip2014
UV activation of polymeric high aspect ratio microstructures: ramifications in antibody surface loading for circulating tumor cell selection.
Article in Lab on a chip, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
47 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Circulating Tumor Cell Detection for Therapeutic and Prognostic Roles in Breast Cancer.Cancer medicine · 2025Pooled it
- Exploiting Device Deformability for Fluid and Particle Manipulation.Small (Weinheim an der Bergstrasse, Germany) · 2026Review
- Microfluidics for Blood Disorders and Hematological Disease Monitoring and Modeling.International journal of molecular sciences · 2026Review
- The evolution of nanopore measurements: from biological out-of-plane pores to plastic in-plane pores.Lab on a chip · 2026Review
- Microfluidic Affinity Selection of B-Lineage Cells from Peripheral Blood for Minimal Residual Disease Monitoring in Pediatric B-Type Acute Lymphoblastic Leukemia Patients.International journal of molecular sciences · 2024Article
- Novel thermoplastic microvalves based on an elastomeric cyclic olefin copolymer.Lab on a chip · 2024Article
- A pragmatic, stepped-wedge, hybrid type II trial of interoperable clinical decision support to improve venous thromboembolism prophylaxis for patients with traumatic brain injury.Implementation science : IS · 2024Article
- Detection and identification of single ribonucleotide monophosphates using a dual in-plane nanopore sensor made in a thermoplasticLab on a chip · 2024Article
- Exploring the role of polymers to overcome ongoing challenges in the field of extracellular vesicles.Journal of extracellular vesicles · 2023Review
- Integrated "lab-on-a-chip" microfluidic systems for isolation, enrichment, and analysis of cancer biomarkers.Lab on a chip · 2023Review
- Assessing Breast Cancer Molecular Subtypes Using Extracellular Vesicles' mRNA.Analytical chemistry · 2023Article
- The Fabrication and Bonding of Thermoplastic Microfluidics: A Review.Materials (Basel, Switzerland) · 2022Review
- Application of Microfluidics in Detection of Circulating Tumor Cells.Frontiers in bioengineering and biotechnology · 2022Review
- Tailoring Thermoplastic In-Plane Nanopore Size by Thermal Fusion Bonding for the Analysis of Single Molecules.ACS sensors · 2021Article
- Analytical Technologies for Liquid Biopsy of Subcellular Materials.Annual review of analytical chemistry (Palo Alto, Calif.) · 2021Article
- Detection of circulating tumor cells: Advances and critical concerns.Oncology letters · 2021Review
- Solid-phase XRN1 reactions for RNA cleavage: application in single-molecule sequencing.Nucleic acids research · 2021Article
- Electrokinetic identification of ribonucleotide monophosphates (rNMPs) using thermoplastic nanochannels.Journal of chromatography. A · 2021Article
- Isolation and analysis methods of extracellular vesicles (EVs).Extracellular vesicles and circulating nucleic acids · 2021Article
- Affinity enrichment of extracellular vesicles from plasma reveals mRNA changes associated with acute ischemic stroke.Communications biology · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
The need to activate thermoplastic surfaces using robust and efficient methods has been driven by the fact that replication techniques can be used to produce microfluidic devices in a high production mode and at low cost, making polymer microfluidics invaluable for in vitro diagnostics, such as circulating tumor cell (CTC) analysis, where device disposability is critical to mitigate artifacts associated with sample carryover. Modifying the surface chemistry of thermoplastic devices through activation techniques can be used to increase the wettability of the surface or to produce functional scaffolds to allow for the covalent attachment of biologics, such as antibodies for CTC recognition. Extensive surface characterization tools were used to investigate UV activation of various surfaces to produce uniform and high surface coverage of functional groups, such as carboxylic acids in microchannels of different aspect ratios. We found that the efficiency of the UV activation process is highly dependent on the microchannel aspect ratio and the identity of the thermoplastic substrate. Colorimetric assays and fluorescence imaging of UV-activated microchannels following EDC/NHS coupling of Cy3-labeled oligonucleotides indicated that UV-activation of a PMMA microchannel with an aspect ratio of ~3 was significantly less efficient toward the bottom of the channel compared to the upper sections. This effect was a consequence of the bulk polymer's damping of the modifying UV radiation due to absorption artifacts. In contrast, this effect was less pronounced for COC. Moreover, we observed that after thermal fusion bonding of the device's cover plate to the substrate, many of the generated functional groups buried into the bulk rendering them inaccessible. The propensity of this surface reorganization was found to be higher for PMMA compared to COC. As an example of the effects of material and microchannel aspect ratios on device functionality, thermoplastic devices for the selection of CTCs from whole blood were evaluated, which required the immobilization of monoclonal antibodies to channel walls. From our results, we concluded the CTC yield and purity of isolated CTCs were dependent on the substrate material with COC producing the highest clinical yields for CTCs as well as better purities compared to PMMA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.