Evidence map›Paper›PMID 23893860›Full record

ArticleElectrophoresis2013

Modeling of misalignment effects in microfluidic interconnects for modular bio-analytical chip applications.

Sudheer D Rani, Taehyun Park, Byoung Hee You, Steve A Soper, Michael C Murphy, Dimitris E Nikitopoulos

Abstract read
In one paragraph

Article in Electrophoresis, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sudheer D RaniWashington University in St. Louis, Department of Radiology, Saint Louis, MO, USA.
Taehyun Park
Byoung Hee You
Steve A Soper
Michael C Murphy
Dimitris E Nikitopoulos

Funding

MICRO-INSTRUMENT PLATFORMS FOR GENETIC-BASED ANALYSESR24EB002115 · NIBIB · LOUISIANA STATE UNIV A&M COL BATON ROUGE · PI SOPER, STEVEN ALLAN · 2003 to 2004
$1.3M
NIBIB NIH HHS NIH R24-EB002115NIBIB NIH HHS R24 EB002115
6 · The paper itself

Abstract

Minimizing misalignments during the interconnection of microfluidic modules is extremely critical to develop a fully integrated microfluidic device. Misalignments arising during chip-to-chip or world-to-chip interconnections can be greatly detrimental to efficient functioning of microfluidic devices. To address this problem, we have performed numerical simulations to investigate the effect of misalignments arising in three types of interconnection methods: (i) end-to-end interconnection (ii) channel overlap when chips are stacked on top of each other, and (iii) tube-in-reservoir misalignment occurring due to the offset between the external tubing and the reservoir. For the case of end-to-end interconnection, the effect of misalignment was investigated for 0, 13, 50, 58, and 75% reduction in the available flow area at the location of geometrical misalignment. In the channel overlap interconnection method, various possible misalignment configurations were simulated by maintaining the same amount of misalignment (75% flow area reduction). The effect of misalignment in a tube-in-reservoir interconnection was investigated by positioning the tube at an offset of 164 μm from the reservoir center. All the results were evaluated in terms of the equivalent length of a straight pipe. The effect of Reynolds number (Re) was also taken into account by performing additional simulations of aforementioned cases at Re ranging between 0.075 ≤ Re ≤ 75. Correlations were developed and the results were interpreted in terms of equivalent length (Le ). Equivalent length calculations revealed that the effect of misalignment in tube-in-reservoir interconnection method was the least significant when compared to the other two methods of interconnection.

Indexed as

Computer SimulationEquipment DesignMicrofluidic Analytical TechniquesModels, TheoreticalArea changeGeometric misalignmentMicrofluidics

Identifiers

PMID23893860
PMCPMC4477268

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.