ArticleJournal of virological methods2013
Performance evaluation of ExiStation HBV diagnostic system for hepatitis B virus DNA quantitation.
Article in Journal of virological methods, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Detection of hepatitis B virus infection: A systematic review.World journal of hepatology · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The performance of a recently developed real-time PCR system, the ExiStation HBV diagnostic system, for quantitation of hepatitis B virus (HBV) in human blood was evaluated. The detection limit, reproducibility, cross-reactivity, and interference were evaluated as measures of analytical performance. For the comparison study, 100 HBV-positive blood samples and 100 HBV-negative samples from Korean Blood Bank Serum were used, and the results of the ExiStation HBV system showed good correlation with those obtained using the Cobas TaqMan (r2=0.9931) and Abbott real-time PCR systems (r2=0.9894). The lower limit of detection was measured as 9.55 IU/mL using WHO standards and the dynamic range was linear from 6.68 to 6.68×10(9) IU/mL using cloned plasmids. The within-run coefficient of variation (CV) was 9.4%, 2.1%, and 1.1%, and the total CV was 11.8%, 3.6%, and 1.7% at a concentration of 1.92 log10 IU/mL, 3.88 log10 IU/mL, and 6.84 log10 IU/mL, respectively. No cross-reactivity or interference was detected. The ExiStation HBV diagnostic system showed satisfactory analytical sensitivity, excellent reproducibility, no cross-reactivity, no interference, and high agreement with the Cobas TaqMan and Abbott real-time PCR systems, and is therefore a useful tool for the detection and monitoring of HBV infection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.