ArticleEJNMMI research2013
Post-radioembolization yttrium-90 PET/CT - part 2: dose-response and tumor predictive dosimetry for resin microspheres.
Article in EJNMMI research, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 78 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
78 citing papers in PubMed, 3 syntheses or guidelines pooled it, 169 citations in OpenAlex.
- AAPM Medical Physics Practice Guideline 14.a: Yttrium-90 microsphere radioembolization.Journal of applied clinical medical physics · 2024Guideline
- To 1000 Gy and back again: a systematic review on dose-response evaluation in selective internal radiation therapy for primary and secondary liver cancer.European journal of nuclear medicine and molecular imaging · 2021Pooled it
- Pooled it
- Efficacy and evaluation of dose-response relationship of selective internal radiation therapy for the management of liver metastases in neuroendocrine neoplasia.European journal of nuclear medicine and molecular imaging · 2026Trial
- Additional hepaticBMC gastroenterology · 2018Trial
- Effects of dose heterogeneity on response and toxicity afterEuropean journal of nuclear medicine and molecular imaging · 2026Article
- Comparison of pre-therapeutic [European journal of nuclear medicine and molecular imaging · 2026Article
- Multimodal imaging techniques in Yttrium-90 radioembolization for hepatocellular carcinoma: a modality-oriented clinical review.Frontiers in oncology · 2026Review
- Voxel-based dosimetry for predicting treatment response to transarterial radioembolization in hepatocellular carcinoma: significance of intratumoral dose distribution.EJNMMI physics · 2025Article
- Comparative voxel-based dosimetry with pre-treatment Tc-99m SPECT/CT and post-treatment Y-90 PET/MRI for radioembolization with Y-90 microspheres.Annals of nuclear medicine · 2025Article
- Advances and Emerging Techniques in Y-90 Radioembolization for Hepatocellular Carcinoma.Cancers · 2025Review
- Spatial distribution of fractionally administered holmium microspheres in non-tumorous human liver tissue: how livers survive transarterial radioembolisation.EJNMMI research · 2025Article
- The Estimation Value ofCurrent radiopharmaceuticals · 2025Article
- An international phantom study of inter-site variability in Technetium-99m image quantification: analyses from the TARGET radioembolization study.EJNMMI physics · 2024Article
- Prospective comparison of positron emission tomography (PET)/magnetic resonance and PET/computed tomography dosimetry in hepatic malignant neoplastic disease afterJournal of gastrointestinal oncology · 2024Article
- Article
- Article
- Predictive Value of [Diagnostics (Basel, Switzerland) · 2023Article
- Predictive value ofEJNMMI research · 2023Article
- Using Deep Learning to Predict Treatment Response in Patients with Hepatocellular Carcinoma Treated with Y90 Radiation Segmentectomy.Journal of digital imaging · 2023Article
18 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
20 authors at 7 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCoincidence imaging of low-abundance yttrium-90 (90Y) internal pair production by positron emission tomography with integrated computed tomography (PET/CT) achieves high-resolution imaging of post-radioembolization microsphere biodistribution. Part 2 analyzes tumor and non-target tissue dose-response by 90Y PET quantification and evaluates the accuracy of tumor 99mTc macroaggregated albumin (MAA) single-photon emission computed tomography with integrated CT (SPECT/CT) predictive dosimetry.
methodsRetrospective dose quantification of 90Y resin microspheres was performed on the same 23-patient data set in part 1. Phantom studies were performed to assure quantitative accuracy of our time-of-flight lutetium-yttrium-oxyorthosilicate system. Dose-responses were analyzed using 90Y dose-volume histograms (DVHs) by PET voxel dosimetry or mean absorbed doses by Medical Internal Radiation Dose macrodosimetry, correlated to follow-up imaging or clinical findings. Intended tumor mean doses by predictive dosimetry were compared to doses by 90Y PET.
resultsPhantom studies demonstrated near-perfect detector linearity and high tumor quantitative accuracy. For hepatocellular carcinomas, complete responses were generally achieved at D70 > 100 Gy (D70, minimum dose to 70% tumor volume), whereas incomplete responses were generally at D70 < 100 Gy; smaller tumors (<80 cm3) achieved D70 > 100 Gy more easily than larger tumors. There was complete response in a cholangiocarcinoma at D70 90 Gy and partial response in an adrenal gastrointestinal stromal tumor metastasis at D70 53 Gy. In two patients, a mean dose of 18 Gy to the stomach was asymptomatic, 49 Gy caused gastritis, 65 Gy caused ulceration, and 53 Gy caused duodenitis. In one patient, a bilateral kidney mean dose of 9 Gy (V20 8%) did not cause clinically relevant nephrotoxicity. Under near-ideal dosimetric conditions, there was excellent correlation between intended tumor mean doses by predictive dosimetry and those by 90Y PET, with a low median relative error of +3.8% (95% confidence interval, -1.2% to +13.2%).
conclusionsTumor and non-target tissue absorbed dose quantification by 90Y PET is accurate and yields radiobiologically meaningful dose-response information to guide adjuvant or mitigative action. Tumor 99mTc MAA SPECT/CT predictive dosimetry is feasible. 90Y DVHs may guide future techniques in predictive dosimetry.
Identifiers
What OpenQuestion holds
Registered trials