ArticleDer Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft2013
[Tube versus trabeculectomy study].
Article in Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03166566 (Laminar Drainage Implant), which is not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Laminar Drainage Implant: Safety of a Novel Surgical Treatment for Refractory Glaucoma.
Who cites it
1 citing paper in PubMed, 11 citations in OpenAlex.
- [Possibilities and limitations of glaucoma surgery].Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Epibulbar glaucoma drainage devices have been only slightly modified since their introduction more than 40 years ago. Having been used primarily in only difficult cases with a poor prognosis (and therefore with poor clinical results) the recently published trabeculectomy versus tube study (TVT) led to a change in our understanding of these devices. In this study epibulbar glaucoma drainage devices (here the Baerveldt device) were employed for early implantation (in some cases as primary glaucoma surgery intervention). Being sceptically monitored the results over the first 5 year clearly showed an almost equal or even better outcome in comparison to trabeculectomy. Despite these good results a critical evaluation seems mandatory mainly because of the unsolved problems concerning late complications. Late tube erosion with subsequent blebitis and enophthalmitis as well as late base plate encapsulation need to be mentioned here. The latter leads to thick fibrous tissue around the base plate resulting in an increase of intraocular pressure (IOP). Late corneal decompensation is also a late complication the pathomechanism of which is only poorly understood. Solving and treating such late complications are often troublesome and time consuming. Future experiments should lead to development of new drainage implant designs and the bulk material should be enhanced and optimized to increase clinical surgical results.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.