Evidence map›Paper›PMID 23852521›Full record

ArticleAdvances in experimental medicine and biology2013

Radiation oxygen biology with pulse electron paramagnetic resonance imaging in animal tumors.

Gage Redler, Martyna Elas, Boris Epel, Eugene D Barth, Howard J Halpern

Open access · greenAbstract read
In one paragraph

Article in Advances in experimental medicine and biology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 2 countries.

Gage RedlerCenter for EPR Imaging In Vivo Physiology, Chicago, IL, USA.
Martyna ElasCenter for EPR Imaging In Vivo Physiology, Chicago, IL, USA.
Boris EpelCenter for EPR Imaging In Vivo Physiology, Chicago, IL, USA.
Eugene D BarthCenter for EPR Imaging In Vivo Physiology, Chicago, IL, USA.
Howard J HalpernCenter for EPR Imaging In Vivo Physiology, Chicago, IL, USA. h-halpern@uchicago.edu.
University of Chicago · US

Funding

Very Low Frequency EPR Imaging in Vivo Phisiology P41 EB02034P41EB002034 · NIBIB · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2017
$16.1M
Radiation Biology of EPR Oxygen ImagesR01CA098575 · NCI · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2022
$4.5M
NCI NIH HHS R01 CA098575NCI NIH HHS R01 CA98575NIBIB NIH HHS P41 EB002034
6 · The paper itself

Abstract

The reduced oxygen in tumors (hypoxia) generates radiation resistance and limits tumor control probability (TCP) at radiation doses without significant normal tissue complication. Modern radiation therapy delivery with intensity-modulated radiation therapy (IMRT) enables complex, high-dose gradient patterns, which avoid sensitive human tissues and organs. EPR oxygen images may allow selection of more resistant parts of a tumor to which to deliver more radiation dose to enhance TCP. EPR O2 images are obtained using injected narrow-line, low relaxation rate trityl spin probes that enable pulse radiofrequency EPR O2 images of tumors in the legs of mice, rats, and rabbits, the latter exceeding 4 cm in size. Low relaxation rates of trityls have enabled novel T1-, rather than T2-, based oximetry, which provides near absolute pO2 imaging. Tomographic image formation and filtered back projection reconstruction are used to generate these images with fixed, linear stepped gradients. Images obtained both with T2 and T1 oximetric images have demonstrated the complex in vivo mechanism explaining the unexpected efficacy of TNFerade, a radiation-inducible adenoviral construct to locally produce TNF-induced vascular as well as radiation damage [1, 2]. The unexpected efficacy of large-dose radiation fractions is seen to be due to an interaction between host microvasculature and tumor cells producing a prompt (15 min) postradiation hypoxia, paralyzing tumor cell repair, and sensitizing tumors. Finally, cure of tumors treated to a single 50 % control dose shows a significant dependence on EPR O2 image hypoxic fractions, best shown with the fraction of voxels less than 10 Torr (HF10). We show that these O2 images provide a quantitative basis for measuring tumor and normal tissue response to abnormally low O2 levels. Measurements of vascular endothelial growth factor (VEGF) production in a specific syngeneic mouse fibrosarcoma, FSa versus fraction of tissue voxels with pO2 less than 10 Torr, produced a slope of 0.14 pg VEGF protein/mg total protein/% HF10. We argue that this quantification may be diagnostic of tumor versus normal tissue, and it may be etiologic in the development of malignancy.

Indexed as

AnimalsCell HypoxiaElectron Spin Resonance SpectroscopyMiceNeoplasmsOximetryOxygenRabbitsRadiobiologyRatsVascular Endothelial Growth Factor AOxygenVascular Endothelial Growth Factor A

Identifiers

PMID23852521
PMCPMC4319364
OpenAlexW1851679508

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.