Evidence map›Paper›PMID 23850955›Full record

ArticleJournal of clinical microbiology2013

Duplex molecular assay intended for point-of-care diagnosis of influenza A/B virus infection.

Liang-Ta Wu, Isabelle Thomas, Martin D Curran, Joanna S Ellis, Surendra Parmar, Neha Goel, Pia I Sharma, Jean-Pierre Allain, Helen H Lee

Open access · hybridAbstract readComparative StudyEvaluation Study
In one paragraph

Article in Journal of clinical microbiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 23 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Liang-Ta WuDiagnostics Development Unit, Department of Haematology, University of Cambridge, Cambridge, United Kingdom.
Isabelle Thomas
Martin D Curran
Joanna S Ellis
Surendra Parmar
Neha Goel
Pia I Sharma
Jean-Pierre Allain
Helen H Lee
University of Cambridge · GBAddenbrooke's Hospital · GBInstitut Scientifique de Santé Publique · BEPublic Health England · GB

Funding

Wellcome Trust
6 · The paper itself

Abstract

Early diagnosis and management of influenza virus infection directly correlates with the effectiveness in disease control. Current molecular influenza virus tests were designed for use in diagnostic testing facilities, where sophisticated equipment and highly trained technicians are available. A longer turnaround time for the centralized testing than when testing near the sample source could delay the initiation of medical intervention, thereby reducing the efficacy of antiviral treatment. The new assay, the SAMBA (simple amplification-based assay) Flu duplex test, is a dipstick-based molecular assay developed to provide a simple, accurate, and cost-effective solution for the diagnosis of influenza A/B viruses intended for near-patient testing. The test presents an alternative format of influenza virus molecular testing that utilizes isothermal amplification and visual detection of nucleic acid on a test strip. The entire test procedure (extraction, amplification, and detection) is integrated into an enclosed semiautomated system. Analytically, the SAMBA Flu duplex test detects 95 and 85 copies of viral genomes for influenza A and B viruses, respectively, with no cross-reactivity observed against other common respiratory pathogens. The clinical performance was established by blind testing of 328 nasal/throat and nasopharyngeal swab specimens from the United Kingdom and Belgium and comparing the results with the quantitative reverse transcription-PCR method routinely used in two public health laboratories. The SAMBA Flu duplex test showed a clinical sensitivity and specificity of 100% and 97.9% for influenza virus A and 100% and 100% for influenza virus B. The test provides a new technology that could facilitate simple and timely identification of influenza virus infection, potentially resulting in more efficient control measures.

Indexed as

Point-of-Care SystemsBelgiumHumansInfluenza A virusInfluenza B virusInfluenza, HumanMolecular Diagnostic TechniquesNasal MucosaNasopharynxPharynxSensitivity and SpecificityUnited KingdomVirology

Identifiers

PMID23850955
PMCPMC3754654
OpenAlexW2134572066

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.