Evidence map›Paper›PMID 23845960›Full record

ArticleNature protocols2013

Microfluidic mixer designed for performing single-molecule kinetics with confocal detection on timescales from milliseconds to minutes.

Bengt Wunderlich, Daniel Nettels, Stephan Benke, Jennifer Clark, Sascha Weidner, Hagen Hofmann, Shawn H Pfeil, Benjamin Schuler

Abstract read
PubMed Publisher
In one paragraph

Article in Nature protocols, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 37 papers.

0numbers the graph read from it
0cells of the map it votes in
37citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

37 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. A TeZla micromixer for interrogating the early and broad folding landscape of G-quadruplex via multistage velocity descending.Proceedings of the National Academy of Sciences of the United States of America · 2024
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Review
  15. Article
  16. Article
  17. Article
  18. Microfluidic Contact Lenses.Small (Weinheim an der Bergstrasse, Germany) · 2018
    Article
  19. Protein folding transition path times from single molecule FRET.Current opinion in structural biology · 2018
    Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Bengt WunderlichDepartment of Biochemistry, University of Zurich, Zurich, Switzerland.
Daniel Nettels
Stephan Benke
Jennifer Clark
Sascha Weidner
Hagen Hofmann
Shawn H Pfeil
Benjamin Schuler

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microfluidic mixing in combination with single-molecule spectroscopy allows the investigation of complex biomolecular processes under non-equilibrium conditions. Here we present a protocol for building, installing and operating microfluidic mixing devices optimized for this purpose. The mixer is fabricated by replica molding with polydimethylsiloxane (PDMS), which allows the production of large numbers of devices at a low cost using a single microfabricated silicon mold. The design is based on hydrodynamic focusing combined with diffusive mixing and allows single-molecule kinetics to be recorded over five orders of magnitude in time, from 1 ms to ∼100 s. Owing to microfabricated particle filters incorporated in the inlet channels, the devices provide stable flow for many hours to days without channel blockage, which allows reliable collection of high-quality data. Modular design enables rapid exchange of samples and mixing devices, which are mounted in a specifically designed holder for use with a confocal microscopy detection system. Integrated Peltier elements provide temperature control from 4 to 37 °C. The protocol includes the fabrication of a silicon master, production of the microfluidic devices, instrumentation setup and data acquisition. Once a silicon master is available, devices can be produced and experiments started within ∼1 d of preparation. We demonstrate the performance of the system with single-molecule Förster resonance energy transfer (FRET) measurements of kinetics of protein folding and conformational changes. The dead time of 1 ms, as predicted from finite element calculations, was confirmed by the measurements.

Indexed as

Protein FoldingCalibrationEquipment DesignFluorescence Resonance Energy TransferKineticsMicrofluidic Analytical TechniquesMicrofluidicsMicrotechnologySiliconTemperatureSilicon

Identifiers

PMID23845960

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.