SynthesisThe Cochrane database of systematic reviews2013
Effect of partogram use on outcomes for women in spontaneous labour at term.
Synthesis in The Cochrane database of systematic reviews, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 40 papers, 7 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
40 citing papers in PubMed, 7 syntheses or guidelines pooled it, 222 citations in OpenAlex.
- Partograph utilization as a decision-making tool and associated factors among obstetric care providers in Ethiopia: a systematic review and meta-analysis.Systematic reviews · 2020Pooled it
- Diagnostic accuracy of the partograph alert and action lines to predict adverse birth outcomes: a systematic review.BJOG : an international journal of obstetrics and gynaecology · 2019Pooled it
- Effect of partograph use on outcomes for women in spontaneous labour at term and their babies.The Cochrane database of systematic reviews · 2018Pooled it
- Strategies for intrapartum foetal surveillance in low- and middle-income countries: A systematic review.PloS one · 2018Pooled it
- A realist review of the partograph: when and how does it work for labour monitoring?BMC pregnancy and childbirth · 2017Pooled it
- Barriers to and incentives for achieving partograph use in obstetric practice in low- and middle-income countries: a systematic review.BMC pregnancy and childbirth · 2014Pooled it
- Caregivers' use of strict criteria for diagnosing active labour in term pregnancy.The Cochrane database of systematic reviews · 2000Pooled it
- Comparing Different Partograph Designs for Use in Standard Labor Care: A Pilot Randomized Trial.Maternal and child health journal · 2018Trial
- Trial
- Use of wind-up fetal Doppler versus Pinard for fetal heart rate intermittent monitoring in labour: a randomised clinical trial.BMJ open · 2015Trial
- Knowledge, attitude, and practice of birth attendants regarding partograph use and its association with birth outcomes: a cross sectional study in Iran.BMC pregnancy and childbirth · 2026Article
- Determinants of uterine rupture among pregnant mothers who gave birth at University of Gondar comprehensive specialized Hospital, Northwest Ethiopia: unmatched case control study.BMC pregnancy and childbirth · 2026Article
- Change management - digitalisation of labor room: A mixed-methods study to assess the level of acceptance of 'Arc Partograph' application to go paperless in labor rooms.European journal of obstetrics & gynecology and reproductive biology: X · 2025Article
- Customization and acceptability of the WHO labor care guide to improve labor monitoring among health workers in Uganda. An iterative development, mixed method study.PLOS global public health · 2024Article
- Utilisation of partogram at a district in the North West Province, South Africa.Health SA = SA Gesondheid · 2024Article
- Enhancing safe motherhood: Effect of novel partograph on labor outcomes and its utility: An Indian perspective.Journal of family medicine and primary care · 2022Article
- Impact of labor characteristics on maternal and neonatal outcomes of labor: A machine-learning model.PloS one · 2022Article
- Insights into the design, development and implementation of a novel digital health tool for skilled birth attendants to support quality maternity care in Kenya.Family medicine and community health · 2021Article
- Amniotic fluid lactate level as a diagnostic tool for prolonged labour.Journal of mother and child · 2020Review
- Article
Corrections and comments
- Updated by
- Update of
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundThe partogram (sometimes known as partograph) is usually a pre-printed paper form on which labour observations are recorded. The aim of the partogram is to provide a pictorial overview of labour, to alert midwives and obstetricians to deviations in maternal or fetal wellbeing and labour progress. Charts often contain pre-printed alert and action lines. An alert line represents the slowest 10% of primigravid women's labour progress. An action line is placed a number of hours after the alert line (usually two or four hours) to prompt effective management of slow progress of labour.
objectivesTo determine the effect of use of partogram on perinatal and maternal morbidity and mortality.To determine the effect of partogram design on perinatal and maternal morbidity and mortality. SEARCH
methodsWe searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 May 2013). SELECTION CRITERIA: Randomised and quasi-randomised controlled trials involving a comparison of partogram with no partogram, or comparison between different partogram designs. DATA COLLECTION AND ANALYSIS: Three review authors independently assessed eligibility, quality and extracted data. When one review author was also the trial author, the two remaining authors assessed the studies independently. MAIN
resultsWe have included six studies involving 7706 women in this review; two studies assessed partogram versus no partogram and the remainder assessed different partogram designs. There was no evidence of any difference between partogram and no partogram in caesarean section (risk ratio (RR) 0.64, 95% confidence interval (CI) 0.24 to 1.70); instrumental vaginal delivery (RR 1.00, 95% CI 0.85 to 1.17) or Apgar score less than seven at five minutes (RR 0.77, 95% CI 0.29 to 2.06) between the groups. When compared to a four-hour action line, women in the two-hour action line group were more likely to require oxytocin augmentation (RR 1.14, 95% CI 1.05 to 1.22). When the three- and four-hour action line groups were compared, caesarean section rate was lowest in the four-hour action line group and this difference was statistically significant (RR 1.70, 95% CI 1.07 to 2.70, n = 613, one trial). When a partogram with a latent phase (composite) and one without (modified) were compared, the caesarean section rate was lower in the partograph without a latent phase (RR 2.45, 95% CI 1.72 to 3.50, n = 743, one trial). AUTHORS'
conclusionsOn the basis of the findings of this review, we cannot recommend routine use of the partogram as part of standard labour management and care. Given the fact that the partogram is currently in widespread use and generally accepted, it appears reasonable, until stronger evidence is available, that partogram use should be locally determined. Further trial evidence is required to establish the efficacy of partogram use.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.