ArticlePloS one2013
A novel implantable glaucoma valve using ferrofluid.
Article in PloS one, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed.
- Fabrication and in vivo testing of a sub-mm duckbill valve for hydrocephalus treatment.Microsystems & nanoengineering · 2024Article
- Synthesis of Fluorous Ferrofluids and Effects of the Nanoparticle Coatings on Field- and Temperature-Dependent Magnetizations.Chemistry of materials : a publication of the American Chemical Society · 2023Article
- Development of a Novel Valve-Controlled Drug-Elutable Microstent for Microinvasive Glaucoma Surgery: In Vitro and Preclinical In Vivo Studies.Translational vision science & technology · 2023Article
- Conventional glaucoma implants and the new MIGS devices: a comprehensive review of current options and future directions.Eye (London, England) · 2021Review
- Advantages and Disadvantages of Using Magnetic Nanoparticles for the Treatment of Complicated Ocular Disorders.Pharmaceutics · 2021Review
- Nanotechnology for Medical and Surgical Glaucoma Therapy-A Review.Advances in therapy · 2020Review
- Potential Therapeutic Usage of Nanomedicine for Glaucoma Treatment.International journal of nanomedicine · 2020Review
- Promising Approach in the Treatment of Glaucoma Using Nanotechnology and Nanomedicine-Based Systems.Molecules (Basel, Switzerland) · 2019Review
- Comparison of two prototypes of a magnetically adjustable glaucoma implant in rabbits.PloS one · 2019Article
- Biocompatible Magnetic Nanocomposite Microcapsules as Microfluidic One-way Diffusion Blocking Valves with Ultra-low Opening Pressure.Materials & design · 2018Article
- Article
- Low-cost rapid prototyping of liquid crystal polymer based magnetic microactuators for glaucoma drainage devices.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2016Article
- Keratoprosthesis: A Review of Recent Advances in the Field.Journal of functional biomaterials · 2016Review
- A Prototype External Magnetic Eyelid Device for Blepharoptosis.Translational vision science & technology · 2014Article
- Removal of Silicone Oil From Intraocular Lens Using Novel Surgical Materials.Translational vision science & technology · 2014Article
- One Year of Glaucoma Research in Review: 2012 to 2013.Asia-Pacific journal of ophthalmology (Philadelphia, Pa.)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo present a novel design of an implantable glaucoma valve based on ferrofluidic nanoparticles and to compare it with a well-established FDA approved valve.
settingMassachusetts Eye & Ear Infirmary, Boston, USA.
methodsA glaucoma valve was designed using soft lithography techniques utilizing a water-immiscible magnetic fluid (ferrofluid) as a pressure-sensitive barrier to aqueous flow. Two rare earth micro magnets were used to calibrate the opening and closing pressure. In-vitro flow measurements were performed to characterize the valve and to compare it to Ahmed™ glaucoma valve. The reliability and predictability of the new valve was verified by pressure/flow measurements over a period of three months and X-ray diffraction (XRD) analysis over a period of eight weeks. In vivo assessment was performed in three rabbits.
resultsIn the in vitro experiments, the opening and closing pressures of the valve were 10 and 7 mmHg, respectively. The measured flow/pressure response was linearly proportional and reproducible over a period of three months (1.8 µl/min at 12 mmHg; 4.3 µl/min at 16 mmHg; 7.6 µl/min at 21 mmHg). X-ray diffraction analysis did not show oxidization of the ferrofluid when exposed to water or air. Preliminary in vivo results suggest that the valve is biocompatible and can control the intraocular pressure in rabbits.
conclusionsThe proposed valve utilizes ferrofluid as passive, tunable constriction element to provide highly predictable opening and closing pressures while maintaining ocular tone. The ferrofluid maintained its magnetic properties in the aqueous environment and provided linear flow to pressure response. Our in-vitro tests showed reliable and reproducible results over a study period of three months. Preliminary in-vivo results were very promising and currently more thorough investigation of this device is underway.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials