Evidence map›Paper›PMID 23824129›Full record

ArticleJournal of radiation research2013

Evaluation of different fiducial markers for image-guided radiotherapy and particle therapy.

Daniel Habermehl, Katrin Henkner, Swantje Ecker, Oliver Jäkel, Jürgen Debus, Stephanie E Combs

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Journal of radiation research, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04684186 (Real-time Guided Stereotactic Radiotherapy in Lung Cancer Using Endovascular Coils for Tumor Marking), which is not on this map. Cited by 48 papers.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed
8.1field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04684186 unknown statusnot on this mapstarted 2016, after this paper: background citation

Real-time Guided Stereotactic Radiotherapy in Lung Cancer Using Endovascular Coils for Tumor Marking: Head-to-head Comparison Between Endovascular and Bronchoscopic Fiducial Marker Insertion

TypeobservationalSponsorCentre Hospitalier Universitaire VaudoisRan2016 to 2026Enrolled60ConditionsLung Cancer, Lung Metastases, RadiotherapyArmsEndovascular fiducial marker insertion, Bronchoscopic fiducial marker insertion
3 · Its place in the literature

Who cites it

48 citing papers in PubMed, 87 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Daniel HabermehlDepartment of Radiation Oncology, University Hospital of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany. daniel.habermehl@med.uni-heidelberg.de
Katrin Henkner
Swantje Ecker
Oliver Jäkel
Jürgen Debus
Stephanie E Combs
Heidelberger Institut für Radioonkologie · DEHeidelberg University · DEUniversity Hospital Heidelberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Modern radiotherapy (RT) techniques are widely used in the irradiation of moving organs. A crucial step in ensuring the correct position of a target structure directly before or during treatment is daily image guidance by computed tomography (CT) or X-ray radiography (image-guided radiotherapy, IGRT). Therefore, combinations of modern irradiation devices and imaging, such as on-board imaging (OBI) with X-rays, or in-room CT such as the tomotherapy system, have been developed. Moreover, combinations of linear accelerators and in-room CT-scanners have been designed. IGRT is of special interest in hypofractionated and radiosurgical treatments where high single doses are applied in the proximity of critical organs at risk. Radiographically visible markers in or in close proximity to the target structure may help to reproduce the position during RT and could therefore be used as external surrogates for motion monitoring. Criteria sought for fiducial markers are (i) visibility in the radiologic modalities involved in radiotherapeutic treatment planning and image guidance, such as CT and kilovoltage (kV) OBI), (ii) low production of imaging artifacts, and (iii) low perturbation of the therapeutic dose to the target volume. Photon interaction with interstitial markers has been shown to be not as important as in particle therapy, where interaction of the particle beam, especially with metal markers, can have a significant impact on treatment. This applies especially with a scanned ion beam. Recently we commenced patient recruitment at our institution within the PROMETHEUS trial, which evaluates a hypofractionation regime, starting with 4 x 10 Gy (RBE), for patients with hepatocellular carcinoma. The aim of this work is, therefore, to evaluate potential implantable fiducial markers for enabling precise patient and thus organ positioning in scanned ion beams. To transfer existing knowledge of marker application from photon to particle therapy, we used a range of commercially available markers of different forms and sizes, consisting of carbon and gold materials, and evaluated them for their potential use in the clinical setup with scanned ion beams at our institution. All markers were implanted in a standardized Alderson phantom and were examined using CT scans and orthogonal kV OBI in our clinical routine protocol. Impact on beam perturbation downstream of the markers in the plateau region of a spread-out Bragg peak (SOBP) was estimated by using radiographic films for clinical proton and carbon ion beams of high and low energies. All tested markers achieved good visibility in CT and kV OBI. Disturbances due to artifacts and dose perturbation were highest in the arbitrarily folded gold and the thickest gold marker, but especially low in the carbon marker. Dose perturbation was highest in the arbitrarily folded gold marker. In summary, the analyzed markers offer promising potential for identifying target structures in our treatment setup at HIT and will soon be used in clinical routine. However, a careful choice of marker, depending on the tumor localization and irradiation strategy, will need to be made.

Indexed as

Fiducial MarkersCarbonEquipment DesignGelatinGoldHeavy Ion RadiotherapyHumansIonsLiver NeoplasmsPhantoms, ImagingPhotonsProton TherapyRadiotherapy DosageRadiotherapy, Image-GuidedTomography, X-Ray ComputedCarbonGelatinGoldIonscarbon ion therapyfiducial markerliver tumorsmoving organsraster-scanning technique

Identifiers

PMID23824129
PMCPMC3700523
OpenAlexW2165512921

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.