Evidence map›Paper›PMID 23814607›Full record

ArticleTherapeutic advances in gastroenterology2013

LINX(®) Reflux Management System in chronic gastroesophageal reflux: a novel effective technology for restoring the natural barrier to reflux.

Luigi Bonavina, Greta Saino, John C Lipham, Tom R Demeester

Abstract read
In one paragraph

Article in Therapeutic advances in gastroenterology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
36citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

36 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. LINXSurgical endoscopy · 2017
    Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Safety of transvenous cardiac defibrillator and magnetic titanium beads system for gastroesophageal reflux disease: a case report.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023
    Article
  10. Article
  11. Article
  12. Observational
  13. Review
  14. Evolution of a novel technology for gastroesophageal reflux disease: a safety perspective of magnetic sphincter augmentation.Diseases of the esophagus : official journal of the International Society for Diseases of the Esophagus · 2021
    Article
  15. Complete endoscopic removal of an eroded magnetic sphincter augmentation device.VideoGIE : an official video journal of the American Society for Gastrointestinal Endoscopy · 2021
    Article
  16. Review
  17. LINXWorld journal of clinical cases · 2020
    Article
  18. Magnetic Sphincter Augmentation and Postoperative Dysphagia: Characterization, Clinical Risk Factors, and Management.Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract · 2020
    Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Luigi BonavinaDivision of General Surgery, Department of Biomedical Sciences for Health, University of Milano School of Medicine, via Morandi 30, 20097 San Donato Milanese, Milan, Italy.
Greta Saino
John C Lipham
Tom R Demeester

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Gastroesophageal reflux disease (GERD) results from incompetency of the lower esophageal sphincter that allows the contents of the stomach to reflux into the esophagus, the airways, and the mouth. The disease affects about 10% of the western population and has a profound negative impact on quality of life. The majority of patients are successfully treated with proton-pump inhibitors, but up to 40% have incomplete relief of symptoms even after dose adjustment. The laparoscopic Nissen fundoplication represents the surgical gold standard, but is largely underused because of the level of technical difficulty and the prevalence of side effects. These factors have contributed to the propensity of patients to continue with medical therapy despite inadequate symptom control and complications of the disease. As a consequence, a significant 'therapy gap' in the treatment of GERD remains evident in current clinical practice. The LINX(®) Reflux Management System (Torax Medical, St. Paul, MN, USA) is designed to provide a permanent solution to GERD by augmenting the sphincter barrier with a standardized, reproducible laparoscopic procedure that does not alter gastric anatomy and is easily reversible. Two single-group trials confirmed that a magnetic device designed to augment the lower esophageal sphincter can be safely and effectively implanted using a standard laparoscopic approach. The device decreased esophageal acid exposure, improved reflux symptoms and quality of life, and allowed cessation of proton-pump inhibitors in the majority of patients.

Indexed as

adenocarcinomaBarrett’sesophagitisfundoplicationgastroesophageal reflux diseaseheartburnlower esophageal sphincter augmentationNissenproton-pump inhibitorsregurgitation

Identifiers

PMID23814607
PMCPMC3667475

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked