ArticleUpdates in surgery2013
The impact of the Harmonic FOCUS™ on complications in thyroid surgery: a prospective multicenter study.
Article in Updates in surgery, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 4 syntheses or guidelines pooled it, 23 citations in OpenAlex.
- Sutureless FOCUS harmonic scalpel versus clamp-and-tie techniques for thyroidectomy: a meta-analysis of 43 randomized controlled trials.International journal of surgery (London, England) · 2024Pooled it
- The role of LigaSure™ and Harmonic Scalpel in the preservation of recurrent laryngeal nerve during thyroidectomy.Annals of the Royal College of Surgeons of England · 2022Pooled it
- Neuromonitoring in endoscopic and robotic thyroidectomy.Updates in surgery · 2017Pooled it
- Gastrectomy and D2 Lymphadenectomy for Gastric Cancer: A Meta-Analysis Comparing the Harmonic Scalpel to Conventional Techniques.International journal of surgical oncology · 2015Pooled it
- Total Thyroidectomy with Harmonic Scalpel Combined with Gelatin Thrombin Hemostatic: A Focus on the Elderly Population-A Multicentric Study.Medicina (Kaunas, Lithuania) · 2025Article
- The impact of the ultrasonic, bipolar and integrated energy devices in the adrenal gland surgery: literature review and our experience.BMC surgery · 2019Review
- A comparison of surgical outcomes and complications between hemostatic devices for thyroid surgery: a network meta-analysis.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2017Review
- Article
- A systematic review and meta-analysis of Harmonic Focus in thyroidectomy compared to conventional techniques.Thyroid research · 2015Review
- INCIDENTAL PARATHYROIDECTOMY DURING THYROID SURGERY - RISK, PREVENTION AND CONTROVERSIES; AN EVIDENCE-BASED REVIEW.Acta endocrinologica (Bucharest, Romania : 2005)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In recent years, newer tools have been developed and used in thyroid surgery. This study compared patients with multinodular goiter undergoing thyroidectomy using the Harmonic FOCUS™ with patients undergoing the clamp-and-tie technique. Medical records of 268 patients with multinodular goiter undergoing thyroidectomy from December 2006 to July 2011 in two centers in Italy, the Department of Surgery of Pisa and the General Surgery Unit of Grosseto, were prospectively evaluated. Patients were divided into group A (Harmonic FOCUS™ Shear), and group B (clamp-and-tie technique). Patient demographics and specific end points analyzed included age, sex, diagnosis, thyroid gland volume, operative time, complications, need for clips and hemostatic agents, need for suction balloon, postoperative blood loss, and postoperative hospital length of stay. 141 patients were included in group A, and 127 patients were included in group B. The two groups were similar in age, sex ratio, indication for surgery, and thyroid volume. Mean operative time was significantly shorter with the Harmonic FOCUS™ Shear (51.8 min) than with the clamp-and-tie technique (70.9 min). The mean postoperative amount obtained from the suction balloon was similar. Vascular clips were needed significantly more frequently in group A (26.2 %) than in group B (12.5 %), whereas the need for hemostatic agents was significantly reduced in group A (4.2 %) compared with group B (14.9 %). The decision to leave a suction drain at the end of the operation occurred significantly more frequently in group B (96 %) than in group A (78 %). Mean postoperative hospital length of stay was 2.02 days in group A compared with 3.1 days in group B, which was significant. No definitive postoperative complications were documented in either group, except a higher rate, but not statistically significant, of permanent hypoparathyroidism in group B versus Group A. Transient laryngeal nerve injury was similar in both groups, whereas transient hypoparathyroidism occurred more frequently in Group B (4.7 %) than in Group A (2.4 %). Harmonic FOCUS device was significantly associated with lower rate of postoperative transient hypocalcemia, decreased operative time, shorter hospitalization, and lesser need for hemostatic agents and postoperative drain balloon. These results might be considered "indirect" money-saving factors, despite the cost of the device, especially in countries where the cost of thyroidectomy is influenced also by the hospital length of stay.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.