Evidence map›Paper›PMID 23789889›Full record

Trial reportThe New England journal of medicine2013

Threshold-based insulin-pump interruption for reduction of hypoglycemia.

Richard M Bergenstal, David C Klonoff, Satish K Garg, Bruce W Bode, Melissa Meredith, Robert H Slover, Andrew J Ahmann, John B Welsh, Scott W Lee, Francine R Kaufman and 1 more

3 registry-linked trialsAbstract readMulticenter StudyRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in The New England journal of medicine, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 241 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
241citing papers in PubMed, 4 pooled it
48.2field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT01497938 phase3completednot on this map

ASPIRE (Automation to Simulate Pancreatic Insulin Response): Pivotal In Home Study to Determine Safety and Efficacy of the LGS Feature in Sensor-augmented Pumps

TypeinterventionalSponsorMedtronic MiniMed, Inc.Ran2011 to 2013Enrolled247ConditionsType 1 DiabetesArmsMedtronic MMT-754 Veo Insulin pump testing Low Glucose Suspend (LGS) feature, Medtronic (NO LGS FEATURE ) using Paradigm® Revel™2.0 Pump
NCT02657213 nacompletednot on this mapstarted 2016, after this paper: background citation

Study of Minimed 640G Insulin Pump With SmartGuard in Prevention of Low Glucose Events in Adults With Type 1 Diabetes at Risk of Severe Hypoglycemia

TypeinterventionalSponsorUniversity Hospital, GrenobleRan2016 to 2017Enrolled20ConditionsDiabetes, Type 1ArmsMinimed 640G with smartguard activated, Minimed 640G with smartguard off
NCT03040414 nacompletednot on this mapstarted 2019, after this paper: background citation

Home Use of MD-Logic Automated Insulin Delivery System: Safety and Efficacy

TypeinterventionalSponsorHealthPartners InstituteRan2019 to 2020Enrolled126ConditionsType 1 Diabetes MellitusArmsMedtronicMinimed 670G 3.0 hybrid closed loop system, Medtronic Minimed 670G 4.0 AHCL with Guardian Sensor (3) continuous glucose monitoring sensor.
3 · Its place in the literature

Who cites it

241 citing papers in PubMed, 4 syntheses or guidelines pooled it, 649 citations in OpenAlex.

  1. [Diabetes technology (Update 2026)].Wiener klinische Wochenschrift · 2026
    Guideline
  2. Guideline
  3. Guideline
  4. Guideline
  5. Trial
  6. Trial
  7. Trial
  8. Trial
  9. The Association Between HbADiabetes care · 2020
    Trial
  10. Trial
  11. Trial
  12. Trial
  13. Trial
  14. Trial
  15. Trial
  16. Trial
  17. Sensor Life and Overnight Closed Loop: A Randomized Clinical Trial.Journal of diabetes science and technology · 2017
    Trial
  18. Trial
  19. Trial
  20. Trial

181 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors at 7 institutions in 2 countries.

Richard M BergenstalInternational Diabetes Center at Park Nicollet, Minneapolis, MN 55416, USA. richard.bergenstal@parknicollet.com
David C Klonoff
Satish K Garg
Bruce W Bode
Melissa Meredith
Robert H Slover
Andrew J Ahmann
John B Welsh
Scott W Lee
Francine R Kaufman
ASPIRE In-Home Study Group
Medtronic (Ireland) · IEUniversity of Colorado Denver · USAtlanta Diabetes Associates · USMills Peninsula Health Services · USOregon Health & Science University · USPark Nicollet Clinic · USUniversity of Wisconsin–Madison · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe threshold-suspend feature of sensor-augmented insulin pumps is designed to minimize the risk of hypoglycemia by interrupting insulin delivery at a preset sensor glucose value. We evaluated sensor-augmented insulin-pump therapy with and without the threshold-suspend feature in patients with nocturnal hypoglycemia.

methodsWe randomly assigned patients with type 1 diabetes and documented nocturnal hypoglycemia to receive sensor-augmented insulin-pump therapy with or without the threshold-suspend feature for 3 months. The primary safety outcome was the change in the glycated hemoglobin level. The primary efficacy outcome was the area under the curve (AUC) for nocturnal hypoglycemic events. Two-hour threshold-suspend events were analyzed with respect to subsequent sensor glucose values.

resultsA total of 247 patients were randomly assigned to receive sensor-augmented insulin-pump therapy with the threshold-suspend feature (threshold-suspend group, 121 patients) or standard sensor-augmented insulin-pump therapy (control group, 126 patients). The changes in glycated hemoglobin values were similar in the two groups. The mean AUC for nocturnal hypoglycemic events was 37.5% lower in the threshold-suspend group than in the control group (980 ± 1200 mg per deciliter [54.4 ± 66.6 mmol per liter] × minutes vs. 1568 ± 1995 mg per deciliter [87.0 ± 110.7 mmol per liter] × minutes, P<0.001). Nocturnal hypoglycemic events occurred 31.8% less frequently in the threshold-suspend group than in the control group (1.5 ± 1.0 vs. 2.2 ± 1.3 per patient-week, P<0.001). The percentages of nocturnal sensor glucose values of less than 50 mg per deciliter (2.8 mmol per liter), 50 to less than 60 mg per deciliter (3.3 mmol per liter), and 60 to less than 70 mg per deciliter (3.9 mmol per liter) were significantly reduced in the threshold-suspend group (P<0.001 for each range). After 1438 instances at night in which the pump was stopped for 2 hours, the mean sensor glucose value was 92.6 ± 40.7 mg per deciliter (5.1 ± 2.3 mmol per liter). Four patients (all in the control group) had a severe hypoglycemic event; no patients had diabetic ketoacidosis.

conclusionsThis study showed that over a 3-month period the use of sensor-augmented insulin-pump therapy with the threshold-suspend feature reduced nocturnal hypoglycemia, without increasing glycated hemoglobin values. (Funded by Medtronic MiniMed; ASPIRE ClinicalTrials.gov number, NCT01497938.).

Indexed as

Insulin Infusion SystemsAdolescentAdultAgedArea Under CurveBlood GlucoseDiabetes Mellitus, Type 1FemaleGlycated HemoglobinHumansHypoglycemiaHypoglycemic AgentsInsulinMaleMiddle AgedYoung AdultBlood GlucoseGlycated HemoglobinHypoglycemic AgentsInsulin

Identifiers

PMID23789889
OpenAlexW2102877966

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.