ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2013
Quality assessment of cardiovascular magnetic resonance in the setting of the European CMR registry: description and validation of standardized criteria.
Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05346094 (A Multicenter Investigation of Cardiac Normal Values of Morphology, Function and Tissue Characteristics by Magnetic Resonance Imaging), which is not on this map. Cited by 45 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Multicenter Investigation of Cardiac Normal Values of Morphology, Function and Tissue Characteristics by Magnetic Resonance Imaging
Who cites it
45 citing papers in PubMed.
- Comparison of acquisition time and dose for late gadolinium enhancement imaging at 3.0 T in patients with chronic myocardial infarction using Gd-BOPTA.European radiology · 2014Trial
- Pre-Imaging Clinical Factors Associated With Cardiac MR Image Quality Using Large Language Model-Enabled Data Extraction.Journal of magnetic resonance imaging : JMRI · 2026Article
- Validation of a novel three-dimensional ultrafast cardiac magnetic resonance imaging protocol in adolescents: a non-inferiority study compared with the two-dimensional gold standard.Pediatric radiology · 2026Article
- Applicability of Stress Cardiac Magnetic Resonance Imaging in Patients With Cardiac Implantable Devices: A Systematic Review.Cardiology research and practice · 2026Review
- Sex-specific structural and functional cardiac remodeling during healthy aging assessed by cardiovascular magnetic resonance.Clinical research in cardiology : official journal of the German Cardiac Society · 2025Article
- Full free-breathing motion-corrected cardiac cine and late gadolinium enhancement MRI: feasibility and validation in clinical practice.The international journal of cardiovascular imaging · 2025Article
- First-pass perfusion imaging using cardiovascular magnetic resonance in patients with various cardiac implantable electronic devices.Clinical research in cardiology : official journal of the German Cardiac Society · 2025Article
- Four-Dimensional Flow MRI for Cardiovascular Evaluation (4DCarE): A Prospective Non-Inferiority Study of a Rapid Cardiac MRI Exam: Study Protocol and Pilot Analysis.Diagnostics (Basel, Switzerland) · 2024Article
- A Comprehensive Review of Percutaneous and Surgical Left Atrial Appendage Occlusion.Journal of cardiovascular development and disease · 2024Review
- The impact of severe obesity on image quality and ventricular function assessment in echocardiography and cardiac MRI.The international journal of cardiovascular imaging · 2024Article
- Optimizing Clinical Cardiac MRI Workflow through Single Breath-Hold Compressed Sensing Cine: An Evaluation of Feasibility and Efficiency.Journal of clinical medicine · 2024Article
- Studying the Influence of Finite Element Mesh Size on the Accuracy of Ventricular Tachycardia Simulation.Reviews in cardiovascular medicine · 2023Article
- Free-Breathing and Single-Breath Hold Compressed Sensing Real-Time MRI of Right Ventricular Function in Children with Congenital Heart Disease.Diagnostics (Basel, Switzerland) · 2023Article
- Cardiac MRI-based right-to-left ventricular blood pool T2 relaxation times ratio correlates with exercise capacity in patients with chronic heart failure.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023Article
- Free-breathing cardiac cine MRI with compressed sensing real-time imaging and retrospective motion correction: clinical feasibility and validation.European radiology · 2023Article
- Translating principles of quality control to cardiovascular magnetic resonance: assessing quantitative parameters of the left ventricle in a large cohort.Scientific reports · 2023Article
- Free-breathing cardiovascular cine magnetic resonance imaging using compressed-sensing and retrospective motion correction: accurate assessment of biventricular volume at 3T.Japanese journal of radiology · 2023Article
- Performance of artificial intelligence for biventricular cardiovascular magnetic resonance volumetric analysis in the clinical setting.The international journal of cardiovascular imaging · 2022Article
- Comparison of cardiac volumetry using real-time MRI during free-breathing with standard cine MRI during breath-hold in children.Pediatric radiology · 2022Article
- Left atrial adaptation in ischemic heart disease: insights from a cardiovascular magnetic resonance study.The international journal of cardiovascular imaging · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry.
methodsThirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student.
resultsThe global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83.
conclusionsThe described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.