ArticleThe Journal of bone and joint surgery. American volume2013
Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.
Article in The Journal of bone and joint surgery. American volume, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Which design and biomaterial factors affect clinical wear performance of total disc replacements? A systematic review.Clinical orthopaedics and related research · 2014Pooled it
- Effect of Axial and Coronal Malalignment on Polyethylene Stresses in Lumbosacral Total Joint Replacement: A Finite Element Study.Bioengineering (Basel, Switzerland) · 2026Article
- Spinal implant wear particles: Generation, characterization, biological impacts, and future considerations.iScience · 2025Review
- Long-term outcomes following lumbar total disc replacement with M6-L.Journal of spine surgery (Hong Kong) · 2022Article
- Midterm osteolysis-induced aseptic failure of the M6-C™ cervical total disc replacement secondary to polyethylene wear debris.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022Article
- ICR in human cadaveric specimens: An essential parameter to consider in a new lumbar disc prosthesis design.North American Spine Society journal · 2020Article
- Article
- Immunobiology of periprosthetic inflammation and pain following ultra-high-molecular-weight-polyethylene wear debris in the lumbar spine.Expert review of clinical immunology · 2018Review
- We Need to Talk about Lumbar Total Disc Replacement.International journal of spine surgery · 2018Article
- Lumbar disc replacement surgery-successes and obstacles to widespread adoption.Current reviews in musculoskeletal medicine · 2017Review
- Evaluation of impingement behaviour in lumbar spinal disc arthroplasty.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2015Article
- UHMWPE wear debris and tissue reactions are reduced for contemporary designs of lumbar total disc replacements.Clinical orthopaedics and related research · 2015Article
- ISASS Policy Statement - Lumbar Artificial Disc.International journal of spine surgery · 2015Article
- Preparation, characterization, and in vitro osteoblast functions of a nano-hydroxyapatite/polyetheretherketone biocomposite as orthopedic implant material.International journal of nanomedicine · 2014Article
- Characteristics of highly cross-linked polyethylene wear debris in vivo.Journal of biomedical materials research. Part B, Applied biomaterials · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
backgroundWear, oxidation, and particularly rim impingement damage of ultra-high molecular weight polyethylene total disc replacement components have been observed following surgical revision. However, neither in vitro testing nor retrieval-based evidence has shown the effect(s) of impingement on the characteristics of polyethylene wear debris. Thus, we sought to determine (1) differences in polyethylene particle size, shape, number, or biological activity that correspond to mild or severe rim impingement and (2) in an analysis of all total disc replacements, regardless of impingement classification, whether there are correlations between the extent of regional damage and the characteristics of polyethylene wear debris.
methodsThe extent of dome and rim damage was characterized for eleven retrieved polyethylene cores obtained at revision surgery after an average duration of implantation of 9.7 years (range, 4.6 to 16.1 years). Polyethylene wear debris was isolated from periprosthetic tissues with use of nitric acid and was imaged with use of environmental scanning electron microscopy. Subsequently, particle size, shape, number, biological activity, and chronic inflammation scores were determined.
resultsGrouping of particles by size ranges that represented high biological relevance (<0.1 to 1-μm particles), intermediate biological relevance (1 to 10-μm particles), and low biological relevance (>10-μm particles) revealed an increased volume fraction of particles in the <0.1 to 1-μm and 1 to 10-μm size ranges in the mild-impingement cohort as compared with the severe-impingement cohort. The increased volume fractions resulted in a higher specific biological activity per unit particle volume in the mild-impingement cohort than in the severe-impingement cohort. However, functional biological activity, which is normalized by particle volume (mm3/g of tissue), was significantly higher in the severe-impingement cohort. This increase was due to a larger volume of particles in all three size ranges. In both cohorts, the functional biological activity correlated with the chronic inflammatory response, and the extent of rim penetration positively correlated with increasing particle size, number, and functional biological activity.
conclusionsThe results of this study suggest that severe rim impingement increases the production of biologically relevant particles from motion-preserving lumbar total disc replacement components. LEVEL OF EVIDENCE: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials