ReviewEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2014
Treatment options for vertebral fractures an overview of different philosophies and techniques for vertebral augmentation.
Review in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2014. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 18 citations in OpenAlex.
- Efficacy of Percutaneous Vertebroplasty Versus Placebo and Conservative Treatment in Osteoporotic Vertebral Fractures: An Updated Systematic Review and Meta-Analysis of Randomized Clinical Trials.Diagnostics (Basel, Switzerland) · 2025Review
- Vertebral balloon kyphoplasty versus vertebral body stenting in non-osteoporotic vertebral compression fractures at the thoracolumbar junction: a comparative radiological study and finite element analysis (BONEXP study).European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021Article
- [Vertebroplasty and kyphoplasty : A critical statement].Der Radiologe · 2020Review
- Appropriateness criteria for treatment of osteoporotic vertebral compression fractures.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2018Review
- Unwarranted regional variation in vertebroplasty and kyphoplasty in Switzerland: A population-based small area variation analysis.PloS one · 2018Article
- Percutaneous vertebral augmentation in fragility fractures-indications and limitations.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2017Review
- Radiofrequency-Targeted Vertebral Augmentation: Case Report of a Patient with 7 Osteoporotic Vertebral Fractures in a Variant of Osteogenesis Imperfecta.Case reports in orthopedics · 2017Article
- Supramolecular Metallo-Bioadhesive for Minimally Invasive Use.Advanced materials (Deerfield Beach, Fla.) · 2016Article
- Third-generation percutaneous vertebral augmentation systems.Journal of spine surgery (Hong Kong) · 2016Review
- [Spinal fractures].Zeitschrift fur Gerontologie und Geriatrie · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeFor more than 30 years, minimally invasive surgical procedures have been available to stabilize the fractured vertebrae by cement augmentation leading to significant pain relief, a distinct improvement in quality of life and decreased mortality for patients suffering from osteoporotic vertebral compression fractures. This overview article is designed to provide information on the wide range of augmentation methods previously tested and clinically applied in surgery in an attempt to compile the clinically relevant information on safety and efficacy in the published literature.
methodBased on an extensive literature review on the topic of "vertebral fractures--surgical augmentation techniques" we summarized the results of published clinical trials and experimental testing which address clinically relevant questions. The selection of the publications in reference books and scientific journals covers the time period from the end of the 1970s until the present.
resultsThe final selection of more than 50 publications with, in the opinion of the authors, clinically relevant data led to the following results, which can be of significance for clinical application. The prerequisites for the success of all augmentation methods include the earliest possible surgical intervention, optimal technical equipment and an experienced, interdisciplinary team, as well as thorough consideration of the situation of the individual patient. The selection of the material for vertebral augmentation depends on the surgical method. The material of choice remains polymethylmethacrylate (PMMA), and the best record of efficacy and safety is displayed by radiofrequency kyphoplasty with ultrahigh-viscosity cement. Regarding clinical efficacy and safety, there are many convincing documentations showing superiority of vertebroplasty and kyphoplasty in comparison with conservative therapeutic regimens. Initial results of clinical studies with additional implants indicate a trend toward further improvement in clinical success and suggest possible broader clinical possibilities of application.
conclusionModern, minimally invasive augmentation techniques represent a real alternative to conservative treatment of patients with vertebral fractures. Further technical and clinical development in this area should aim at optimizing procedural safety while continuing to achieve comparably good results to current methods. Minimizing damage to the remaining trabecular structures as well as to adjacent vertebral disks and vertebrae should be paramount of importance. SUMMARY: Options for the treatment of vertebral fractures: Reductions in bone density and pathological changes in bone structure are associated with an elevated risk of fractures, which can lead to decisive functional impairment, pain, and a host of further comorbidities. Vertebral augmentation can be considered as an alternative conservative treatment, in order to achieve immediate and lasting pain relief as well as improvement in functional impairment. To achieve greater safety, instrumentation for transpedicular access and incorporation of radiopacifiers in PMMA for vertebroplasty were developed in mid-eighties. Balloon kyphoplasty was introduced in the end nineties, and results of prospective, randomized clinical studies have confirmed the safety and efficacy; the destruction of the remaining native spongiosa structures during balloon expansion is viewed as a disadvantage of this method. The two step method of cavity creation followed by cement delivery known as kyphoplasty has been further refined and developed by and varied by technology/procedural developments. This includes most the radiofrequency kyphoplasty (DFINE Inc., San Jose, CA, USA), in which ultrahigh-viscosity cement is delivered at a controlled delivery rate, following producing a bone sparing size and side specific cavity which minimizes loss of spongiosa, allowing for mechanical stability upon interdigitation of cement into that remaining trabecular bone. This combination has been shown to preserve vertebral structures and reduces the risk of leakages. Finally, systems have been available in which cement augmentation of implants to enhance mechanical stability of the implants or the overall fracture is constructed by load sharing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.