ArticleAJNR. American journal of neuroradiology2013
Stent retriever use for retrieval of displaced microcoils: a consecutive case series.
Article in AJNR. American journal of neuroradiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
29 citing papers in PubMed.
- Case report and literature review of stent detachment after vertebral artery stenting.Frontiers in cardiovascular medicine · 2026Article
- Human placenta as a biological vascular model for endovascular training.Frontiers in neurology · 2026Article
- Migrated coil and damaged stent removal during coil embolization, using an additional, retrievable stent: A case report.Journal of cerebrovascular and endovascular neurosurgery · 2023Article
- Retrieval of Migrated Coils From Distal Cerebral Vasculature Using Stent Retriever: A Case Series.Cureus · 2023Article
- Parent artery stenting as a rescue management for stretched coils during cerebral aneurysms embolization: Report of three cases and review of literature.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2022Review
- Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review.Cureus · 2022Article
- Emergency surgical removal of a migrated coil during embolization of a giant internal carotid artery aneurysm: illustrative case.Journal of neurosurgery. Case lessons · 2022Article
- Retrieval of Displaced Woven EndoBridge Intrasaccular Flow Disruptor Using Solitaire Platinum Revascularization Device.Neurointervention · 2022Article
- Treatment of Ruptured and Nonruptured Aneurysms Using a Semisolid Iodinated Embolic Agent.Advanced materials (Deerfield Beach, Fla.) · 2022Article
- Bailout stentectomy of 47 self-expandable intracranial stents.Journal of neurointerventional surgery · 2022Article
- Bailout Technique for Coil Unraveling with a KUSABI Exchange Catheter: A Case Report.Journal of neuroendovascular therapy · 2022Article
- Rescue Maneuver of Migrated Coil Using the ERIC Device after Previous Attempts with Conventional Stentrievers.Neurointervention · 2021Article
- Rescue balloon-assisted remodeling technique for protrusion of coil loop: A case report.Medicine · 2021Article
- Endovascular retrieval of a dislocated pushable coil in the common hepatic artery using a cerebral stent retriever.CVIR endovascular · 2021Article
- The Removal of a Fractured Guidewire During Mechanical Thrombectomy. a Case Report.Journal of critical care medicine (Universitatea de Medicina si Farmacie din Targu-Mures) · 2021Article
- Removal of a Distally Migrated and Wedged Small Detachable Coil Using a 4MAX Penumbra Reperfusion Catheter.Clinical neuroradiology · 2019Article
- Dislocation of a WEB Device into the Middle Cerebral Artery : Removal with the Alligator Retrieval Device.Clinical neuroradiology · 2019Article
- Apologia of transparency: answer to the letter of L. Pierot.Neuroradiology · 2019Article
- Retrieval of Migrated Volume Coils Using Different Clot Retrievers in a Porcine Model.Clinical neuroradiology · 2018Article
- Magnetic wires: A novel design for neuroendovascular coil retrieval.Experimental and therapeutic medicine · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
summaryCoil displacement during endovascular coiling procedures may require coil retrieval in the context of flow limitation or thromboembolic risk. No standard recommended method of coil retrieval exists. We present a consecutive series of 14 patients with displaced coil during aneurysm coiling in whom the complication was effectively managed with the use of a stent retriever system. Two illustrative cases from the 14 are described, and technical notes are detailed regarding use of the technique. The use of stent retrievers presents a simple, safe, and effective choice for removal of prolapsed coils during aneurysm coiling.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.