Evidence map›Paper›PMID 23749240›Full record

ArticleInternational urogynecology journal2013

Mesh retraction correlates with vaginal pain and overactive bladder symptoms after anterior vaginal mesh repair.

A Rogowski, P Bienkowski, A Tosiak, M Jerzak, P Mierzejewski, W Baranowski

Abstract read
PubMed Publisher
In one paragraph

Article in International urogynecology journal, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 1 pooled it
5.0field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 1 synthesis or guideline pooled it, 49 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Observational
  10. Review
  11. Ultrasound imaging in urogynecology - state of the art 2016.Przeglad menopauzalny = Menopause review · 2016
    Article
  12. Textile properties of synthetic prolapse mesh in response to uniaxial loading.American journal of obstetrics and gynecology · 2016
    Article
  13. Host response to synthetic mesh in women with mesh complications.American journal of obstetrics and gynecology · 2016
    Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Imaging of slings and meshes.Australasian journal of ultrasound in medicine · 2014
    Review
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

A RogowskiDepartment of Gynecology and Oncological Gynecology, Military Institute of Medicine, 128 Szaserow Street, 04-141, Warsaw, Poland, arogowski@op.pl.
P Bienkowski
A Tosiak
M Jerzak
P Mierzejewski
W Baranowski
Military Institute · RUInstitute of Psychiatry and Neurology · PLWojskowy Instytut Medycyny Lotniczej · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introduction and hypothesisThe aim of the present study was to determine possible correlations between mesh retraction after anterior vaginal mesh repair and de novo stress urinary incontinence (SUI), overactive bladder (OAB), and vaginal pain symptoms.

methodsOne hundred and three women with symptomatic prolapse of the anterior vaginal wall, stages 3 and 4 based on the Pelvic Organ Prolapse Quantification (POP-Q) system, underwent Prolift anterior™ implantation. At a 6-month follow-up, the patients were interviewed for de novo SUI, OAB, and vaginal pain, and underwent an introital/transvaginal ultrasound examination to measure the mesh length in the midsagittal plane.

resultsMesh retraction was significantly larger in a subgroup of patients (n = 20; 19.4 %) presenting de novo OAB symptoms on the follow-up assessment compared with those without this complication (5.0 cm vs. 4.3 cm; p < 0.05). Mesh retraction was also significantly larger in a subgroup of patients (n = 23; 22.3 %) reporting postoperative vaginal pain compared with the women who did not report any postoperative vaginal pain (5.3 cm vs. 4.2 cm; p < 0.01). A significant correlation was found between mesh retraction and the severity of vaginal pain (R = 0.4, p < 0.01). Mesh retraction did not differ between patients with de novo SUI symptoms and those without this complication.

conclusionsMesh retraction assessed on ultrasound examination after anterior vaginal mesh repair may correlate with de novo OAB symptoms and vaginal pain.

Indexed as

AdultAgedAged, 80 and overFemaleHumansMiddle AgedPolypropylenesPostoperative PainProsthesis FailureSuburethral SlingsSurgical MeshUrinary Bladder, OveractiveUrinary Incontinence, StressUterine ProlapseVaginaPolypropylenes

Identifiers

PMID23749240
OpenAlexW2033286925

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.