Observational studyJournal of clinical monitoring and computing2013
The impact of systemic vascular resistance on the accuracy of the FloTrac/Vigileo™ system in the perioperative period of cardiac surgery: a prospective observational comparison study.
Observational study in Journal of clinical monitoring and computing, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.
- Agreement of minimally invasive pulse wave analysis with pulmonary artery and transpulmonary thermodilution cardiac output measurements in perioperative and intensive care medicine: a systematic review and meta-analysis.British journal of anaesthesia · 2026Pooled it
- Study of the accuracy of a radial arterial pressure waveform cardiac output measurement device after cardiac surgery.Journal of cardiothoracic surgery · 2023Observational
- Physiologic and hemodynamic changes in patients undergoing open abdominal cytoreductive surgery with hyperthermic intraperitoneal chemotherapy.The Journal of international medical research · 2021Observational
- Effective evaluation of arterial pulse waveform analysis by two-dimensional stroke volume variation-stroke volume index plots.Journal of clinical monitoring and computing · 2017Article
- Agreement between stroke volume measured by oesophageal Doppler and uncalibrated pulse contour analysis during fluid loads in severe aortic stenosis.Journal of clinical monitoring and computing · 2015Observational
- The ability of the Vigileo-FloTrac system to measure cardiac output and track cardiac output changes during one-lung ventilation.Journal of clinical monitoring and computing · 2015Article
- Comparison of Goal-Directed Hemodynamic Optimization Using Pulmonary Artery Catheter and Autocalibrated Arterial Pressure Waveform Analysis Vigileo-FloTrac™ System in On-Pump Coronary Artery Bypass Graft Surgery: A Randomized Controlled Studya.Anesthesia, essays and researchesArticle
- Comparison of pulmonary artery catheter, echocardiography, and arterial waveform analysis monitoring in predicting the hemodynamic state during and after cardiac surgery.International journal of critical illness and injury scienceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
FloTrac/Vigileo™ system is based on arterial pressure waveform analysis arterial pressure-based CO (APCO). Therefore, systemic vascular resistance (SVR) can influence the accuracy of APCO. The purpose of this study is to evaluate the relationship between SVR and the accuracy of APCO. We managed 50 consecutive patients in the perioperative period of cardiac surgery with FloTrac/Vigileo™ system (v. 3.02) and Swan-Ganz catheter/Vigilance™ system pulmonary artery catheter-based CO (PAC-CO) simultaneously. Continuous hemodynamic measurement using both methods was performed every 20 s from the induction of anesthesia to PAC removal 4 h after extubation. A total of 11,092 (intraoperative), 38,455 (postoperative, pre-extubation), and 44,235 (postoperative, post-extubation) data pairs were finally analyzed. Bland-Altman analysis revealed that in the intraoperative [postoperative pre-extubation, post-extubation] period, the bias was 0.5 [0.1, 0.0] L/min and the limits of agreement ranged from -2.4 to 3.3 [-2.2 to 2.4, -2.4 to 2.3] L/min. The percentage error was 60.3 [54.5, 48.5] %. Regression analysis of the systemic vascular resistance index (SVRI) and the bias between APCO and PAC-CO showed that the bias was positively correlated to the SVRI. Subanalysis based on SVR with Lin's concordance correlation coefficient revealed that relatively satisfactory concordance was found in the normal-SVR group (concordance correlation coefficient ρ c = 0.51-0.56) regardless of vasoactive agent use. The accuracy of the FloTrac/Vigileo™ System (v. 3.02) is relatively satisfactory in the condition with normal SVR regardless of vasoactive agent use. Positive correlation between the bias and SVR can be the clue to the more effective use of FloTrac/Vigileo™ system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials