Evidence map›Paper›PMID 23747795›Full record

Trial reportTranslational research : the journal of laboratory and clinical medicine2013

First in-human intraoperative imaging of HCC using the fluorescence goggle system and transarterial delivery of near-infrared fluorescent imaging agent: a pilot study.

Yang Liu, Yi-Ming Zhao, Walter Akers, Zhao-You Tang, Jia Fan, Hui-Chuan Sun, Qing-Hai Ye, Lu Wang, Samuel Achilefu

Registry-linked trialOpen access · greenAbstract readClinical TrialRandomized Controlled Trial
In one paragraph

Trial report in Translational research : the journal of laboratory and clinical medicine, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02316795 (Evaluation of Fluorescence Imaging in Sentinel Lymph Node Biopsy for Breast Cancer and Melanoma), which is not on this map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
3.9field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02316795 early_phase1completednot on this mapstarted 2014, after this paper: background citation

Evaluation of Fluorescence Imaging in Sentinel Lymph Node Biopsy for Breast Cancer and Melanoma

TypeinterventionalSponsorWashington University School of MedicineRan2014 to 2015Enrolled20ConditionsBreast Cancer, Cancer of Breast, Cancer of the Breast, MelanomaArmsSentinel lymph node biopsy, Goggle-based device with light-emitting diodes (LED), Indocynanine Green
3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 52 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Indocyanine Green Fluorescence-Guided Surgery for Gastrointestinal Tumors: A Systematic Review.Annals of surgery open : perspectives of surgical history, education, and clinical approaches · 2022
    Review
  6. Article
  7. Article
  8. Article
  9. NaNature communications · 2019
    Article
  10. TricarbocyanineChemical science · 2018
    Article
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Yang Liu *Department of Radiology Washington University, St. Louis, MO 63110, USA.
Yi-Ming Zhao *Department of Liver Surgery, Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai, P.R., China.
Walter AkersDepartment of Radiology Washington University, St. Louis, MO 63110, USA.
Zhao-You TangDepartment of Liver Surgery, Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai, P.R., China.
Jia FanDepartment of Liver Surgery, Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai, P.R., China.
Hui-Chuan SunDepartment of Liver Surgery, Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai, P.R., China.
Qing-Hai YeDepartment of Liver Surgery, Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai, P.R., China.
Lu WangDepartment of Liver Surgery, Liver Cancer Institute, Zhongshan Hospital, Fudan University, Shanghai, P.R., China.
Samuel AchilefuDepartment of Radiology Washington University, St. Louis, MO 63110, USA.
Washington University in St. Louis · USZhongshan Hospital · CNFudan University · CN

Funding

Task Specific Project 3: Diffuse Optical TomographyU54CA136398 · NCI · WASHINGTON UNIVERSITY · PI WANG, LIHONG · 2008 to 2012
$6.0M
DEVELOPMENT OF GOGGLE SYSTEM FOR FLUORESCENCE IMAGE-GUIDED SURGERYR01CA171651 · NCI · WASHINGTON UNIVERSITY · PI ACHILEFU, SAMUEL · 2013 to 2017
$2.8M
Quantitative Optical Imaging of Molecular Processes in Preclinical Cancer ModelsK01OD010935 · OD · WASHINGTON UNIVERSITY · PI AKERS, WALTER JOHN · 2012 to 2014
$361k
Quantitative Optical Imaging of Molecular Processes in Preclinical Cancer ModelsK01RR026095 · NCRR · WASHINGTON UNIVERSITY · PI AKERS, WALTER JOHN · 2010 to 2011
$245k
NCI NIH HHS R01 CA171651NCI NIH HHS U54 CA136398NCRR NIH HHS K01 RR026095NCRR NIH HHS K01RR026095NIH HHS K01 OD010935
6 · The paper itself

Abstract

Surgical resections remain the primary curative interventions for hepatocellular carcinoma (HCC). However, lack of real-time intraoperative image guidance confines surgeons to subjective visual assessment of the surgical bed, leading to poor visualization of small positive nodules and the extension of diffuse HCC. To address this problem, we developed a wearable fluorescence imaging and display system (fluorescence goggle) for intraoperative imaging of HCCs in human patients. In this pilot study, both intravenous (IV) and transarterial hepatic (TAH) delivery of indocyanine green (ICG) were explored to facilitate fluorescence goggle-mediated HCC imaging. The results show that all primary tumors in patients (n = 4) who received TAH delivery of ICG were identified successfully by the fluorescence goggle. In addition, 6 satellite tumors were also detected by the goggle, 5 of which were neither identifiable via preoperative magnetic resonance imaging (MRI) and computed tomography (CT) nor by visual inspection and palpation. In the group (n = 5) that received ICG intravenously, only 2 of 6 tumors visible by preoperative MRI or CT were identified with the fluorescence goggle, demonstrating the limitation of this delivery route for a non-tumor-selective imaging agent. Comparative analysis shows that the HCC-to-liver florescence contrast detected by the goggle was significantly greater in patients that received TAH than IV delivery of ICG (P = 0.013). This pilot study demonstrates the feasibility of using the fluorescence goggle to identify multifocal lesions and small tumor deposits using TAH ICG delivery in HCC patients.

Indexed as

Carcinoma, HepatocellularFluorescent DyesInfrared RaysMonitoring, IntraoperativeContrast MediaDiagnostic ImagingFeasibility StudiesHumansLiver NeoplasmsMaleContrast MediaFluorescent Dyescomputed tomographyCTFDAFood and Drug AdministrationHCCH&Ehematoxylin and eosinhepatocellular carcinomaICGindocyanine greenintraoperative ultrasonographyintravenousIUSIVLCILiver Cancer Institutemagnetic resonance imagingMRInear infraredNIRPETpositron emission tomographyTAHtransarterial hepatic

Identifiers

PMID23747795
PMCPMC3805674
OpenAlexW2067112320

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.