ArticleInvestigative ophthalmology & visual science2013
Sources of structural autofluorescence in the human trabecular meshwork.
Article in Investigative ophthalmology & visual science, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 22 citations in OpenAlex.
- Visualization of porcine and human aqueous humor outflow tract anatomies with transparency enhancement.Japanese journal of ophthalmology · 2025Article
- Biomechanics of human trabecular meshwork in healthy and glaucoma eyes via dynamic Schlemm's canal pressurization.Computer methods and programs in biomedicine · 2022Article
- Quantification of Pulse-Dependent Trabecular Meshwork Motion in Normal Humans Using Phase-Sensitive OCT.Investigative ophthalmology & visual science · 2018Article
- Deep tissue analysis of distal aqueous drainage structures and contractile features.Scientific reports · 2017Article
- Toward in vivo two-photon analysis of mouse aqueous outflow structure and function.Experimental eye research · 2017Review
- Aqueous Humor Outflow Structure and Function Imaging At the Bench and Bedside: A Review.Journal of clinical & experimental ophthalmology · 2016Article
- Tissue-based multiphoton analysis of actomyosin and structural responses in human trabecular meshwork.Scientific reports · 2016Article
- Optimizing two-photon multiple fluorophore imaging of the human trabecular meshwork.Molecular vision · 2016Article
- New Details of the Human Corneal Limbus Revealed With Second Harmonic Generation Imaging.Investigative ophthalmology & visual science · 2015Article
- Observing live actin in the human trabecular meshwork.Clinical & experimental ophthalmology · 2014Article
- Genomic and proteomic pathophysiology of pseudoexfoliation glaucoma.International ophthalmology clinics · 2014Review
- Tissue-based imaging model of human trabecular meshwork.Journal of ocular pharmacology and therapeutics : the official journal of the Association for Ocular Pharmacology and TherapeuticsReview
- Bleb-related Porcine Lymphatic Outflow is Greater from Subconjunctival compared to Subtenon Blebs.Journal of current glaucoma practiceArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
purposeIn situ 2-photon excitation fluorescence (TPEF) of the human trabecular meshwork (TM) reveals beams of heterogeneous autofluorescence (AF) comprising high intensity fluorescent fibers (AF-high) on a background of lower intensity fluorescence (AF-low). To determine the sources of this AF heterogeneity, we imaged human TM to characterize AF, second harmonic generation (SHG) for collagen, and eosin-labeled fluorescence identifying elastin.
methodsCorneoscleral rims retained after corneal transplantation were incubated with and without eosin, and imaged by TPEF. TPEF was collected through multiphoton bandpass filters to obtain AF, SHG (collagen bandwidth), and eosin-labeled fluorescence images. For qualitative comparisons, near-simultaneous image acquisition pairs of AF-SHG (+/-eosin coincubation), AF-eosin, and SHG-eosin were captured. For quantitative comparisons, multiple regions of interest (ROI) were defined in separate TM beam regions within the uveal and corneoscleral meshwork for image acquisition pairs of AF-SHG (without eosin coincubation) and SHG-eosin. We defined 18 ROI within each acquisition pair as the basis for Manders colocalization analysis. Perfect colocalization was defined as a Manders coefficient (Mcoeff) of 1.
resultsQualitatively and quantitatively, AF-low colocalized with SHG (Mcoeff=1), but not SHG signal-voids. AF-high colocalized with SHG signal-voids (Mcoeff=1), but not the SHG signal. Like AF-high, eosin-labeled fluorescence qualitatively and quantitatively colocalized (Mcoeff=1) with SHG signal-voids, but not the SHG signal.
conclusionsHeterogeneous AF in human TM is comprised of high intensity signal originating from elastin fibers in beam cores and lower intensity signal originating from collagen. These findings are relevant to interpreting structural extracellular matrix signals in AF images of the TM.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.