Evidence map›Paper›PMID 23733019›Full record

ArticleJournal of biomedical optics2013

Accuracy of retinal oximetry: a Monte Carlo investigation.

Wenzhong Liu, Shuliang Jiao, Hao F Zhang

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Advances in Retinal Oximetry.Translational vision science & technology · 2021
    Review
  5. Article
  6. Article
  7. Visible-light optical coherence tomography: a review.Journal of biomedical optics · 2017
    Review
  8. Article
  9. Retinal oxygen: from animals to humans.Progress in retinal and eye research · 2017
    Review
  10. Article
  11. Article
  12. Article
  13. Review
  14. Retinal oxygen extraction in humans.Scientific reports · 2015
    Article
  15. Article
  16. Monte Carlo Investigation of Optical Coherence Tomography Retinal Oximetry.IEEE transactions on bio-medical engineering · 2015
    Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Wenzhong LiuNorthwestern University, Department of Biomedical Engineering, Evanston, Illinois 60208, USA.
Shuliang Jiao
Hao F Zhang

Funding

Novel Antiangiogenic Peptides for Treatment of Exudative AMDR24EY022883 · NEI · UNIVERSITY OF WISCONSIN-MADISON · PI SHEIBANI, NADER · 2013 to 2017
$6.2M
Multimodal Retinal Functional Imaging for Diabetic RetinopathyR01EY019951 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI FAWZI, AMANI A, JIAO, SHULIANG · 2011 to 2015
$3.0M
CCR NIH HHS 1RC4E021357NEI NIH HHS 1R01EY019951NEI NIH HHS 1R24EY022883NEI NIH HHS R01 EY019951NEI NIH HHS R24 EY022883
6 · The paper itself

Abstract

Retinal hemoglobin oxygen saturation (sO2) level is believed to be associated with the pathophysiology of several leading blinding diseases. Methods to properly measure retinal sO2 have been investigated for decades; however, the accuracy of retinal oximetry is still considered to be limited. The Monte Carlo simulation of photon transport in retina to examine how the accuracy of retinal oximetry is affected by local parameters is discussed. Fundus photography was simulated in a multilayer retinal model, in which a single vessel segment with 0.7 sO2 was embedded, at six optical wavelengths. Then, 200 million photons were traced in each simulation to ensure statistically stable results. The optical reflectance and energy deposit were recorded to measure sO2 using both the reflection method (existing retinal oximetry) and a new absorption method, photoacoustic ophthalmoscopy (PAOM). By varying the vessel diameter and melanin concentration in the retinal pigment epithelium, the relative error of sO2 measurement in the reflection method increased with increasing vessel diameter and melanin concentration; in comparison, the sO2 measurement was insensitive to these two parameters in PAOM. The results suggest that PAOM potentially can be a more accurate tool in quantifying retinal sO2.

Indexed as

ChoroidFundus OculiHemoglobinsHumansMelaninsMonte Carlo MethodOphthalmoscopyOximetryOxygenPhotoacoustic TechniquesReproducibility of ResultsRetinaRetinal Pigment EpitheliumRetinal VesselsScleraHemoglobinsMelaninsOxygen

Identifiers

PMID23733019
PMCPMC3669519

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.