Evidence map›Paper›PMID 23730378›Full record

ArticleThe open orthopaedics journal2013

Functionality and Safety of an Ultra-Congruent Rotating Platform Knee Prosthesis at 5.6 Years: More than 5- Year Follow-Up of the e.motion ((®)) UC-TKA.

Jean-Baptiste Chavoix

Abstract read
In one paragraph

Article in The open orthopaedics journal, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Jean-Baptiste ChavoixClinique St. Joseph, 51 Avenue Pres Wilson, 16000 Angouleme, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMobile bearing TKA prostheses were designed to minimize polyethylene wear by increasing implant conformity and reducing stresses between the articulating prosthesis components. It is the purpose of this study to assess the mid-term functionality and clinical outcome associated with a highly congruent mobile platform design, the e.motion(®) UC total knee prosthesis. MATERIAL AND

methodsFunctional and clinical outcomes were assessed after an average of 5.6 years (5.1 - 6.0 years) after total knee arthroplasty in 28 patients (24 women), aged 77.8±7.5 years. The Knee injury and Osteoarthritis Outcome Score (KOOS) was assessed. Secondary outcomes included the Knee Society Score (KSS), radiological evaluation of radiolucent lines and recording of adverse events.

resultsThe average KOOS subscore for the activities of daily life was 77.8 points after 5.6 years. Both the clinical and functional KSS improved at 2.4 and 5.6 years. Two patients showed radiolucent lines at 5.6 years. Adverse events over 5.6 years included 3 subluxations, 1 tilting and 1 misalignment of the patella. None of the prostheses were revised.

conclusionThis pilot study shows promising outcomes for the e.motion(®) UC prosthesis. In the small sample, the implant performed comparably to the LCS prosthesis (the gold standard). There were no loosenings or revisions observed at 5.6 years.

Indexed as

Mobile bearingradiolucent linesrotating platformTKAtotal knee arthroplastyultra-congruent.

Identifiers

PMID23730378
PMCPMC3664449

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.