ArticleJournal of applied physiology (Bethesda, Md. : 1985)2013
Impact of stent mis-sizing and mis-positioning on coronary fluid wall shear and intramural stress.
Article in Journal of applied physiology (Bethesda, Md. : 1985), 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 16 citations in OpenAlex.
- Endovascular approaches to neural interfacing: lessons from cardiovascular technologies.Frontiers in neuroscience · 2026Review
- Simulating the Transmural Mechanical Response of Functionally Graded Arterial Grafts.ACS applied bio materials · 2025Article
- 3D-Printed Radiopaque Bioresorbable Stents to Improve Device Visualization.Advanced healthcare materials · 2022Article
- In vivo comparison of key quantitative parameters measured with 3D peripheral angiography, 2D peripheral quantitative angiography and intravascular ultrasound.The international journal of cardiovascular imaging · 2019Article
- Biomechanical impact of provisional stenting and balloon dilatation on coronary bifurcation: clinical implications.Journal of applied physiology (Bethesda, Md. : 1985) · 2017Article
- Microstructure-based biomechanics of coronary arteries in health and disease.Journal of biomechanics · 2016Review
- Impact of bifurcation dual stenting on endothelial shear stress.Journal of applied physiology (Bethesda, Md. : 1985) · 2015Article
- Three-dimensional virtual surgery models for percutaneous coronary intervention (PCI) optimization strategies.Scientific reports · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 4 institutions in 2 countries.
Funding
Abstract
Stent deployments with geographical miss (GM) are associated with increased risk of target-vessel revascularization and periprocedural myocardial infarction. The aim of the current study was to investigate the underlying biomechanical mechanisms for adverse events with GM. The hypothesis is that stent deployment with GM [longitudinal GM, or LGM (i.e., stent not centered on the lesion); or radial GM, RGM (i.e., stent oversizing)] results in unfavorable fluid wall shear stress (WSS), WSS gradient (WSSG), oscillatory shear index (OSI), and intramural circumferential wall stress (CWS). Three-dimensional computational models of stents and plaque were created using a computer-assisted design package. The models were then solved with validated finite element and computational fluid dynamic packages. The dynamic process of large deformation stent deployment was modeled to expand the stent to the desired vessel size. Stent deployed with GM resulted in a 45% increase in vessel CWS compared with stents that were centered and fully covered the lesion. A 20% oversized stent resulted in 72% higher CWS than a correct sized stent. The linkages between the struts had much higher stress than the main struts (i.e., 180 MPa vs. 80 MPa). Additionally, LGM and RGM reduced endothelial WSS and increased WSSG and OSI. The simulations suggest that both LGM and RGM adversely reduce WSS but increase WSSG, OSI, and CWS. These findings highlight the potential mechanical mechanism of the higher adverse events and underscore the importance of stent positioning and sizing for improved clinical outcome.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.