ArticleMedical physics2013
Reproducibility of intensity-based estimates of lung ventilation.
Article in Medical physics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Technical Note: On the spatial correlation between robust CT-ventilation methods and SPECT ventilation.Medical physics · 2020Article
- Modeling the impact of out-of-phase ventilation on normal lung tissue response to radiation dose.Medical physics · 2020Article
- Robust HU-based CT ventilation from an integrated mass conservation formulation.Medical physics · 2019Article
- The VAMPIRE challenge: A multi-institutional validation study of CT ventilation imaging.Medical physics · 2019Article
- Quantifying ventilation change due to radiation therapy using 4DCT Jacobian calculations.Medical physics · 2018Article
- Quantification of regional deformation of the lungs by non-rigid registration of three-dimensional contrast-enhanced magnetic resonance imaging.Quantitative imaging in medicine and surgery · 2017Article
- The numerical stability of transformation-based CT ventilation.International journal of computer assisted radiology and surgery · 2017Article
- Evaluation of the ΔV 4D CT ventilation calculation method using in vivo xenon CT ventilation data and comparison to other methods.Journal of applied clinical medical physics · 2016Article
- Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements.Medical physics · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
purposeLung function depends on lung expansion and contraction during the respiratory cycle. Respiratory-gated CT imaging and image registration can be used to estimate the regional lung volume change by observing CT voxel density changes during inspiration or expiration. In this study, the authors examine the reproducibility of intensity-based estimates of lung tissue expansion and contraction in three mechanically ventilated sheep and ten spontaneously breathing humans. The intensity-based estimates are compared to the estimates of lung function derived from image registration deformation field.
methods4DCT data set was acquired for a cohort of spontaneously breathing humans and anesthetized and mechanically ventilated sheep. For each subject, two 4DCT scans were performed with a short time interval between acquisitions. From each 4DCT data set, an image pair consisting of a volume reconstructed near end inspiration and a volume reconstructed near end exhalation was selected. The end inspiration and end exhalation images were registered using a tissue volume preserving deformable registration algorithm. The CT density change in the registered image pair was used to compute intensity-based specific air volume change (SAC) and the intensity-based Jacobian (IJAC), while the transformation-based Jacobian (TJAC) was computed directly from the image registration deformation field. IJAC is introduced to make the intensity-based and transformation-based methods comparable since SAC and Jacobian may not be associated with the same physiological phenomenon and have different units. Scan-to-scan variations in respiratory effort were corrected using a global scaling factor for normalization. A gamma index metric was introduced to quantify voxel-by-voxel reproducibility considering both differences in ventilation and distance between matching voxels. The authors also tested how different CT prefiltering levels affected intensity-based ventilation reproducibility.
resultsHigher reproducibility was found for anesthetized mechanically ventilated animals than for the humans for both the intensity-based (IJAC) and transformation-based (TJAC) ventilation estimates. The human IJAC maps had scan-to-scan correlation coefficients of 0.45 ± 0.14, a gamma pass rate 70 ± 8 without normalization and 75 ± 5 with normalization. The human TJAC maps had correlation coefficients 0.81 ± 0.10, a gamma pass rate 86 ± 11 without normalization and 93 ± 4 with normalization. The gamma pass rate and correlation coefficient of the IJAC maps gradually increased with increased smoothing, but were still much lower than those of the TJAC maps.
conclusionsThe transformation-based ventilation maps show better reproducibility than the intensity-based maps, especially in human subjects. Reproducibility was also found to depend on variations in respiratory effort; all techniques were better when applied to images from mechanically ventilated sheep compared to spontaneously breathing human subjects. Nevertheless, intensity-based techniques applied to mechanically ventilated sheep were less reproducible than the transformation-based applied to spontaneously breathing humans, suggesting the method used to determine ventilation maps is important. Prefiltering of the CT images may help to improve the reproducibility of the intensity-based ventilation estimates, but even with filtering the reproducibility of the intensity-based ventilation estimates is not as good as that of transformation-based ventilation estimates.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.