Evidence map›Paper›PMID 23718611›Full record

ArticleMedical physics2013

Magnetothermoacoustics from magnetic nanoparticles by short bursting or frequency chirped alternating magnetic field: a theoretical feasibility analysis.

Daqing Piao, Rheal A Towner, Nataliya Smith, Wei R Chen

Erratum issuedAbstract read
In one paragraph

Article in Medical physics, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

Daqing PiaoSchool of Electrical and Computer Engineering, Oklahoma State University, Stillwater, Oklahoma 74078, USA. daqing.piao@okstate.edu
Rheal A Towner
Nataliya Smith
Wei R Chen

Funding

Therapeutic Evaluation of Magnetic Nanoprobes Specific for Malignant Tumor MarkerR21CA136642 · NCI · OKLAHOMA MEDICAL RESEARCH FOUNDATION · PI TOWNER, RHEAL A · 2009 to 2010
$401k
NCI NIH HHS 1 R21 CA136642-01A1NCI NIH HHS R21 CA136642
6 · The paper itself

Abstract

purposeTo propose an alternative method of thermoacoustic wave generation based on heating of magnetic nanoparticles (MNPs) using alternating magnetic field (AMF).

methodsThe feasibility of thermoacoustic wave generation from MNPs by applying a short-burst of AMF or a frequency-modulated AMF is theoretically analyzed. As the relaxation of MNPs is strongly dependent upon the amplitude and frequency of AMF, either an amplitude modulated, fixed frequency AMF (termed time-domain AMF) or a frequency modulated, constant amplitude AMF (termed frequency-domain AMF) will result in time-varying heat dissipation from MNPs, which has the potential to generate thermoacoustic waves. Following Rosensweig's model of specific power loss of MNPs in a steady-state AMF, the time-resolved heat dissipations of MNPs of superparamagnetic size when exposed to a short bursting of AMF and∕or to a linearly frequency chirped AMF are derived, and the resulted acoustic propagation is presented. Based on experimentally measured temperature-rise characteristics of a superparamagnetic iron-oxide nanoparticle (SPION) matrix in a steady-state AMF of various frequencies, the heat dissipations of the SPION under time-domain and frequency-domain AMF configurations that could have practical utility for thermoacoustic wave generation are estimated.

resultsThe initial rates of the temperature-rise of the SPION matrix were measured at an iron-weight concentration of 0.8 mg∕ml and an AMF frequency of 88.8 kHz to 1.105 MHz. The measured initial rates of temperature-rise were modeled by Rosensweig's theory, and projected to 10 MHz AMF frequency, at which a 1 μs bursting corresponding to a 1.55 mm axial resolution of acoustic detection could contain 10 complete cycles of AMF oscillation and the power dissipation is approximately 84 times of that at 1 MHz. Exposing the SPION matrix to a 1 μs bursting of AMF at 10 MHz frequency and 100 Oe field intensity would produce a volumetric heat dissipation of 7.7 μJ∕cm(3) over the microsecond duration of the AMF burst. If the SPION matrix is exposed to a 1 ms long AMF train at 100 Oe field intensity that chirps linearly from 1 to 10 MHz, the volumetric heat dissipation produced over each 2π phase change of the AMF oscillation is estimated to increase from 0.15 to 1.1 μJ∕cm(3) within the millisecond duration of the chirping of AMF.

conclusionsThe heat dissipations upon SPION (∼1 mg∕ml iron-weight concentration) by a 1 μs bursting of 100 Oe AMF at 10 MHz and a 1 ms train of 100 Oe AMF that chirps linearly from 1 to 10 MHz were estimated to determine the potential of thermal-acoustic wave generation. Although thermoacoustic wave generation from MNPs by time- or frequency-domain AMF applications is predicted, the experimental generation of such a wave remains challenging.

Indexed as

Models, ChemicalComputer SimulationFeasibility StudiesHyperthermia, InducedMagnetic FieldsMagnetite NanoparticlesRadiation DosageSoundMagnetite Nanoparticles

Identifiers

PMID23718611
PMCPMC3669145

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.