Evidence map›Paper›PMID 23712687›Full record

Trial reportExperimental brain research2013

Noise-enhanced kinaesthesia: a psychophysical and microneurographic study.

Edith Ribot-Ciscar, Valérie Hospod, Jean-Marc Aimonetti

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Experimental brain research, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Perception of threshold-level whole-body motion during mechanical mastoid vibration.Journal of vestibular research : equilibrium & orientation · 2018
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Edith Ribot-CiscarAix-Marseille Université, CNRS, NIA UMR 7260, Case B, Centre Saint-Charles, Place Victor Hugo, 13331, Marseille Cedex 03, France. edith.ribot-ciscar@univ-amu.fr
Valérie Hospod
Jean-Marc Aimonetti

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We first explored whether the ability of subjects to detect the direction of slow ramp imposed movements may be improved by the application of mechanical noise to muscle tendons. Movements were plantar/dorsal flexion of the ankle at 0.04°/s, and the amplitude was just sub-threshold for each subject. A white noise signal (random vibration), low-pass filtered to 100 Hz and distributed uniformly in amplitude, was applied to both the extensor and the flexor ankle muscle tendons with four different mean amplitudes (20, 30, 100, 280 μm). The population of subjects was observed to exhibit clear stochastic-type behaviour: their ability to determine the direction of sub-threshold movements significantly increased when the two lower levels of noise were added and subsequently decreased when the noise magnitude was enhanced. Second, using microneurography, we explored the response of 9 primary muscle spindle afferents and 8 cutaneous afferents to the same imposed movements with and without noise application. While these conditions of ankle mobilisation were too small to induce a response in most of the recorded afferents, two muscle afferents exhibited responses that were characteristic of aperiodic stochastic resonance behaviour: the unit movement response was either triggered or improved by the application of an optimal level of noise. All cutaneous afferents were unresponsive to the imposed movements with or without noise application. We conclude that ankle movement sense can be significantly improved by adding an optimal level of mechanical noise to ankle muscle tendons and discuss the optimisation of the response of movement-encoding receptors that may account for this improvement. The application of a mechanical noise on ankle muscle tendons may constitute a means of improving postural stability in subjects with sensory deficits.

Indexed as

VibrationAdultAnkle JointFemaleHumansKinesthesisMaleMovementMuscle SpindlesProprioceptionPsychophysicsYoung Adult

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.