ArticleJournal of the American Society for Mass Spectrometry2013
Fluorometric beam profiling of UV MALDI lasers.
Article in Journal of the American Society for Mass Spectrometry, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- The Influence of MS Imaging Parameters on UV-MALDI Desorption and Ion Yield.Journal of the American Society for Mass Spectrometry · 2019Article
- Matrix Optical Absorption in UV-MALDI MS.Journal of the American Society for Mass Spectrometry · 2018Article
- Probing the Relationship Between Detected Ion Intensity, Laser Fluence, and Beam Profile in Thin Film and Tissue in MALDI MSI.Journal of the American Society for Mass Spectrometry · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The photon distribution (beam profile) of the laser as projected onto the sample is an important variable in matrix assisted laser desorption ionization mass spectrometry (MALDI-MS). Measurement of the beam profile is, therefore, an important factor within MALDI-MS. In this study a simple, low-cost fluorometric laser beam profiling technique is presented and applied in conjunction with MALDI-MS experiments. A comparison of the beam profile information afforded by a commercial system and the fluorometric method is carried out to determine the variation of beam profile for an Nd:YVO4 laser operated between 1 and 25 kHz. The beam profile information can be used, in conjunction with corresponding ion yields, to inform MALDI-MS experiments. The fluorometric beam profiling technique is used to obtain information about the beam dimensions as incident upon the MALDI-MS sample plate in-source. These values are compared with equivalent information obtained from ablation of thin film α-cyano-4-hydroxycinnamic acid (CHCA). In this study, area estimation by ablation provided a value 1.6 times smaller than that obtained by the fluorometric method, demonstrating the need for caution when measuring beam profile and, therefore, fluence, in MALDI-MS. ᅟ
Identifiers
23709039What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.