Evidence map›Paper›PMID 23698262›Full record

ArticleSensors (Basel, Switzerland)2013

Flexible PZT thin film tactile sensor for biomedical monitoring.

Hong-Jie Tseng, Wei-Cheng Tian, Wen-Jong Wu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hong-Jie TsengDepartment of Engineering Science and Ocean Engineering, National Taiwan University, Taipei 10617, Taiwan. hjtseng@mems.iam.ntu.edu.tw
Wei-Cheng Tian
Wen-Jong Wu

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents the development of tactile sensors using the sol-gel process to deposit a PZT thin-film from 250 nm to 1 μm on a flexible stainless steel substrate. The PZT thin-film tactile sensor can be used to measure human pulses from several areas, including carotid, brachial, finger, ankle, radial artery, and the apical region. Flexible PZT tactile sensors can overcome the diverse topology of various human regions and sense the corresponding signals from human bodies. The measured arterial pulse waveform can be used to diagnose hypertension and cardiac failure in patients. The proposed sensors have several advantages, such as flexibility, reliability, high strain, low cost, simple fabrication, and low temperature processing. The PZT thin-film deposition process includes a pyrolysis process at 150 °C/500 °C for 10/5 min, followed by an annealing process at 650 °C for 10 min. Finally, the consistent pulse wave velocity (PWV) was demonstrated based on human pulse measurements from apical to radial, brachial to radial, and radial to ankle. It is characterized that the sensitivity of our PZT-based tactile sensor was approximately 0.798 mV/g.

Indexed as

Biomedical TechnologyCrystallizationDiastoleElectricityFluorocarbon PolymersHumansLeadMonitoring, PhysiologicPliabilityPolyvinylsPulsePulse Wave AnalysisSiliconStainless SteelSystoleTitaniumFluorocarbon PolymersLeadlead titanate zirconatepolyvinylidene fluoridePolyvinylsSiliconStainless SteelTitaniumZirconium

Identifiers

PMID23698262
PMCPMC3690010

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.