Observational studyCritical care (London, England)2013
Continuous on-line glucose measurement by microdialysis in a central vein. A pilot study.
Observational study in Critical care (London, England), 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 31 citations in OpenAlex.
- Accuracy of 2 Different Continuous Glucose Monitoring Systems in Patients Undergoing Cardiac Surgery.Journal of diabetes science and technology · 2017Trial
- The Performance of Continuous Glucose Monitoring During the Intraoperative Period: A Scoping Review.Journal of clinical medicine · 2024Article
- Semi-Implantable Bioelectronics.Nano-micro letters · 2022Review
- A Prospective Observational Feasibility Study of Jugular Bulb Microdialysis in Subarachnoid Hemorrhage.Neurocritical care · 2020Observational
- Accuracy and stability of an arterial sensor for glucose monitoring in a porcine model using glucose clamp technique.Scientific reports · 2020Article
- Head-to-head comparison of two continuous glucose monitoring systems on a cardio-surgical ICU.Journal of clinical monitoring and computing · 2019Article
- In vitro evaluation of an intravenous microdialysis catheter for therapeutic drug monitoring of gentamicin and vancomycin.Pharmacology research & perspectives · 2019Article
- Assessment of changes in blood glucose concentration with intravascular microdialysis.Journal of clinical monitoring and computing · 2018Observational
- Autoregressive Modeling of Drift and Random Error to Characterize a Continuous Intravascular Glucose Monitoring Sensor.Journal of diabetes science and technology · 2018Article
- Point and trend accuracy of a continuous intravenous microdialysis-based glucose-monitoring device in critically ill patients: a prospective study.Annals of intensive care · 2016Article
- Continuous Glucose Monitoring in Patients Undergoing Extracorporeal Ventricular Assist Therapy.PloS one · 2016Article
- Year in review 2013: Critical Care--metabolism.Critical care (London, England) · 2014Review
- Evaluation of intravascular microdialysis for continuous blood glucose monitoring in hypoglycemia: an animal model.Journal of diabetes science and technology · 2014Article
- Glucose control in the ICU: is there a time for more ambitious targets again?Journal of diabetes science and technology · 2014Review
- Continuous glucose control in the ICU: report of a 2013 round table meeting.Critical care (London, England) · 2014Review
- Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.European endocrinology · 2014Article
- Continuous glucose sensors for glycaemic control in the ICU: have we arrived?Critical care (London, England) · 2013Article
- [Assessment and treatment of hyperglycemia in critically ill patients].Revista Brasileira de terapia intensivaReview
Corrections and comments
- Commented on by
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionTight glucose control in the ICU has been proven difficult with an increased risk for hypoglycaemic episodes. Also the variability of glucose may have an impact on morbidity. An accurate and feasible on-line/continuous measurement is therefore desired. In this study a central vein catheter with a microdialysis membrane in combination with an on-line analyzer for continuous monitoring of circulating glucose and lactate by the central route was tested.
methodsA total of 10 patients scheduled for major upper abdominal surgery were included in this observational prospective study at a university hospital. The patients received an extra central venous catheter with a microdialysis membrane placed in the right jugular vein. Continuous microdialysis measurement proceeded for 20 hours and on-line values were recorded every minute. Reference arterial plasma glucose and blood lactate samples were collected every hour.
resultsMean microdialysis-glucose during measurements was 9.8 ± 2.4 mmol/l.No statistical difference in the readings was seen using a single calibration compared to eighth hour calibration (P =0.09; t-test). There was a close agreement between the continuous reading and the reference plasma glucose values with an absolute difference of 0.6+0.8 mmol, or 6.8+9.3% and measurements showed high correlation to plasma readings (r = 0.92). The limit of agreement was 23.0%(1.94 mmol/l) compared to arterial plasma values with a line of equality close to zero.However, in a Clarke-Error Grid 93.3% of the values are in the A-area,and the remaining part in the B-area.Mean microdialysis-lactate was 1.3 ± 1.1 mmol/l. The measurements showed high correlation to the blood readings (r = 0.93).
conclusionContinuous on-line microdialysis glucose measurement in a central vein is a potential useful technique for continuous glucose monitoring in critically ill patients, but more improvements and testing are needed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.