Evidence map›Paper›PMID 23656911›Full record

ArticlePhysics in medicine and biology2013

Betabox: a beta particle imaging system based on a position sensitive avalanche photodiode.

A A Dooraghi, N T Vu, R W Silverman, R Farrell, K S Shah, J Wang, J R Heath, A F Chatziioannou

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Performance evaluation ofMedical physics · 2017
    Article
  5. Article
  6. Article
  7. Article
  8. Fast metabolic response to drug intervention through analysis on a miniaturized, highly integrated molecular imaging system.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2013
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

A A DooraghiCrump Institute for Molecular Imaging, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, CA, USA. alexdooraghi@gmail.com
N T Vu
R W Silverman
R Farrell
K S Shah
J Wang
J R Heath
A F Chatziioannou

Funding

QUANTITATIVE IMAGE ANALYSIS SPECIALIZED RESOURCE COREU54CA119347 · NCI · CALIFORNIA INSTITUTE OF TECHNOLOGY · PI SAWYERS, CHARLES L · 2005 to 2009
$17.8M
UCLA Scholars in Oncologic Molecular lmaging (SOMI)R25CA098010 · NCI · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI PHELPS, MICHAEL E · 2003 to 2013
$5.0M
NCI NIH HHS R25 CA098010NCI NIH HHS R25CA098010NCI NIH HHS U54 CA119347NCI NIH HHS U54CA119347
6 · The paper itself

Abstract

A beta camera has been developed that allows planar imaging of the spatial and temporal distribution of beta particles using a 14 × 14 mm(2) position sensitive avalanche photodiode (PSAPD). This camera system, which we call Betabox, can be directly coupled to microfluidic chips designed for cell incubation or other biological applications. Betabox allows for imaging the cellular uptake of molecular imaging probes labeled with charged particle emitters such as (18)F inside these chips. In this work, we investigate the quantitative imaging capabilities of Betabox for (18)F beta particles, in terms of background rate, efficiency, spatial resolution, and count rate. Measurements of background and spatial resolution are considered both at room temperature (21 °C ± 1 °C) and at an elevated operating temperature (37 °C ± 1 °C), as is often required for biological assays. The background rate measured with a 4 keV energy cutoff is below 2 cph mm(-2) at both 21 and 37 °C. The absolute efficiency of Betabox for the detection of (18)F positron sources in contact with a PSAPD with the surface passivated from ambient light and damage is 46% ± 1%. The lower detection limit is estimated using the Rose Criterion to be 0.2 cps mm(-2) for 1 min acquisitions and a 62 × 62 µm(2) pixel size. The upper detection limit is approximately 21 000 cps. The spatial resolution at both 21 and 37 °C ranges from 0.4 mm FWHM at the center of the field of view (FOV), and degrades to 1 mm at a distance of 5 mm away from center yielding a useful FOV of approximately 10 × 10 mm(2). We also investigate the effects on spatial resolution and sensitivity that result from the use of a polymer based microfluidic chip. For these studies we place varying layers of low-density polyethylene (LDPE) between the detector and the source and find that the spatial resolution degrades by ∼180 µm for every 100 µm of LDPE film. Sensitivity is reduced by half with the inclusion of ∼200 µm of additional LDPE film. Lastly, we demonstrate the practical utilization of Betabox, with an imaging test of its linearity, when coupled to a polydimethylsiloxane microfluidic chip designed for cell based assays.

Indexed as

Beta ParticlesElectrical Equipment and SuppliesMicrofluidic Analytical TechniquesRadionuclide Imaging

Identifiers

PMID23656911
PMCPMC3706465

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.