Evidence map›Paper›PMID 23644854›Full record

ArticleClinics (Sao Paulo, Brazil)2013

Electrical impedance tomography to evaluate air distribution prior to extubation in very-low-birth-weight infants: a feasibility study.

Felipe de Souza Rossi, Ana Cristina Zanon Yagui, Luciana Branco Haddad, Alice D'Agostini Deutsch, Celso Moura Rebello

Open access · goldAbstract readEvaluation Study
In one paragraph

Article in Clinics (Sao Paulo, Brazil), 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.4field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Review
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Felipe de Souza RossiDepartamento Materno-infantil, Hospital Israelita Albert Einstein, São Paulo, SP, Brazil.
Ana Cristina Zanon Yagui
Luciana Branco Haddad
Alice D'Agostini Deutsch
Celso Moura Rebello
Hospital Israelita Albert Einstein · BRUniversidade de São Paulo · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesNasal continuous positive airway pressure is used as a standard of care after extubation in very-low-birth-weight infants. A pressure of 5 cmH2O is usually applied regardless of individual differences in lung compliance. Current methods for evaluation of lung compliance and air distribution in the lungs are thus imprecise for preterm infants. This study used electrical impedance tomography to determine the feasibility of evaluating the positive end-expiratory pressure level associated with a more homogeneous air distribution within the lungs before extubation.

methodsVentilation homogeneity was defined by electrical impedance tomography as the ratio of ventilation between dependent and non-dependent lung areas. The best ventilation homogeneity was achieved when this ratio was equal to 1. Just before extubation, decremental expiratory pressure levels were applied (8, 7, 6 and 5 cmH(2)0; 3 minutes each step), and the pressure that determined the best ventilation homogeneity was defined as the best positive end-expiratory pressure.

resultsThe best positive end-expiratory pressure value was 6.3 ± 1.1 cmH(2)0, and the mean continuous positive airway pressure applied after extubation was 5.2 ± 0.4 cmH(2)0 (p = 0.002). The extubation failure rate was 21.4%. X-Ray and blood gases after extubation were also checked.

conclusionThis study demonstrates that electrical impedance tomography can be safely and successfully used in patients ready for extubation to suggest the best ventilation homogeneity, which is influenced by the level of expiratory pressure applied. In this feasibility study, the best lung compliance was found with pressure levels higher than the continuous positive airway pressure levels that are usually applied for routine extubation.

Indexed as

Airway ExtubationElectric ImpedanceFeasibility StudiesFemaleHumansInfant, NewbornInfant, Very Low Birth WeightLung ComplianceMalePositive-Pressure RespirationReference ValuesReproducibility of ResultsTomographyTreatment Outcome

Identifiers

PMID23644854
PMCPMC3611755
OpenAlexW1987213728

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.