Trial reportAJNR. American journal of neuroradiology2013
Intracranial 4D flow MRI: toward individualized assessment of arteriovenous malformation hemodynamics and treatment-induced changes.
Trial report in AJNR. American journal of neuroradiology, 2013. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 43 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
43 citing papers in PubMed, 1 synthesis or guideline pooled it, 104 citations in OpenAlex.
- Segmentation techniques of brain arteriovenous malformations for 3D visualization: a systematic review.La Radiologia medica · 2022Pooled it
- Characterization of Arterial and Sinus Blood Flow Dynamics in the Rat Brain Using Phase-Contrast MRI.Annals of biomedical engineering · 2026Article
- Clinical applications of 4D flow magnetic resonance imaging in hepatic vascular disorders: practical biomarkers, protocol design, and translational implementation.Quantitative imaging in medicine and surgery · 2026Review
- Jointly Learned 3D Non-Cartesian Sampling With Wave Encoding and Reconstruction for Neurovascular Phase Contrast MRI.Magnetic resonance in medicine · 2026Article
- Repeatability and reproducibility of hemodynamic measurements by intracranial 4D Flow MRI: a multi‑vendor and multi‑software cross‑over comparison study.BMC medical imaging · 2025Article
- Evaluation of Intracranial Arteriovenous Malformations Using Ischemic Stroke Color-Coded Maps Software, a New Rapid Post-Processing Tool in CT Angiography.Journal of clinical medicine · 2025Article
- Hemodynamic relationship with angioarchitecture of cerebral arteriovenous malformation and changes after embolization: a pilot study by 4D flow MR.Quantitative imaging in medicine and surgery · 2024Article
- Considerations for the Use of Stereotactic Radiosurgery to Treat Large Arteriovenous Malformations.Biomedicines · 2024Review
- Hemodynamic evaluation of intracranial arteriovenous malformations: Pre- and post-treatment 2D phase-contrast MRI measurements.Acta radiologica open · 2024Article
- Brain arteriovenous malformation flow after stereotactic radiosurgery: Role of quantitative MRA.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024Article
- Highly accelerated free-breathing real-time 2D flow imaging using compressed sensing and shared velocity encoding.European radiology · 2024Article
- Deep learning phase error correction for cerebrovascular 4D flow MRI.Scientific reports · 2023Article
- Automated hemodynamic assessment for cranial 4D flow MRI.Magnetic resonance imaging · 2023Article
- Accelerated dual-venc 4D flow MRI with variable high-venc spatial resolution for neurovascular applications.Magnetic resonance in medicine · 2022Article
- Challenges in Modeling Hemodynamics in Cerebral Aneurysms Related to Arteriovenous Malformations.Cardiovascular engineering and technology · 2022Article
- Intracranial Flow Velocity Quantification Using Non-Contrast Four-Dimensional Flow MRI: A Prospective Comparative Study with Transcranial Doppler Ultrasound.Diagnostics (Basel, Switzerland) · 2021Article
- Hemodynamic Analysis of Cerebral AVMs with 3D Phase-Contrast MR Imaging.AJNR. American journal of neuroradiology · 2021Article
- Recent progress understanding pathophysiology and genesis of brain AVM-a narrative review.Neurosurgical review · 2021Review
- Article
- Hemodynamics of Cerebral Aneurysms: Connecting Medical Imaging and Biomechanical Analysis.Annual review of biomedical engineering · 2020Review
Corrections and comments
- Commented on by
Authors and funding
10 authors at 1 institution in 1 country.
Funding
Abstract
background and purposeArteriovenous malformations are an important etiology of hemorrhagic stroke. However, current imaging modalities and risk do not provide insights into individual AVM hemodynamics and its role in pathophysiology. The aims of this study are to determine whether intracranial 4D flow MR imaging can provide insights into arteriovenous malformation hemodynamics independent of the Spetzler-Martin grade and to report the changes in flow observed during staged embolization. MATERIALS AND
methodsIntracranial 3D blood flow was assessed in 20 patients with AVM (age = 39 ± 15 years, Spetzler-Martin grade ranging from 1-4) with the use of 4D flow MR imaging (temporal resolution = 45 ms, spatial resolution = [1.2-1.6mm](3)). AVM hemodynamics were visualized by means of time-integrated 3D pathlines depicting the AVM arterial feeding and venous draining patterns over the cardiac cycle. Analysis included the grading of feeding and draining velocities on a 3-point scale (0 = low <25 cm/s, 1 = medium <50 cm/s, 2 = high >50 cm/s). For 4 of 20 patients undergoing 4D flow MR imaging follow-up after staged embolization, peak velocities were quantified in arterial feeders, draining veins, the sagittal sinus, and contralateral arteries.
resultsIn 50% of the cases with Spetzler-Martin grade >2, heterogeneous flow (velocity grade differences >1) was found across arteries and veins. Velocities in draining veins increased from Spetzler-Martin grade = 1 (grading = 0.5 ± 0.6) to Spetzler-Martin grade ≥3 (1.1 ± 0.6), whereas arterial velocities were similar (1.7 ± 0.6 versus 1.5 ± 0.6). In the postembolization subgroup of 4 patients, 4D flow MR imaging demonstrated successively more compact AVM and redistribution of velocities. Changes in arterial and venous velocities during treatment were highly different among individuals.
conclusionsSpetzler-Martin grade does not reflect differences in 3D AVM arterial and venous hemodynamics, and an individual assessment of AVM hemodynamics may be needed for improved lesion characterization. Four-dimensional flow MR imaging may have the potential to monitor and guide embolization treatment planning.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.